2015
DOI: 10.1016/j.nimb.2015.03.064
|View full text |Cite
|
Sign up to set email alerts
|

Decadal 10Be, 26Al and 36Cl QA measurements on the SUERC 5 MV accelerator mass spectrometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
16
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
8

Relationship

7
1

Authors

Journals

citations
Cited by 30 publications
(16 citation statements)
references
References 15 publications
0
16
0
Order By: Relevance
“…All samples were prepared at the University of Vermont Cosmogenic Isotope Laboratory facilities following standard lab protocols [e.g., Corbett et al ., ]. Sample 26 Al/ 27 Al and 10 Be/ 9 Be ratios were measured on the Scottish Universities Environmental Research Centre accelerator mass spectrometry (AMS) laboratory in East Kilbride, Scotland [ Xu et al ., ]. The supporting information provides a detailed description of sample preparation, AMS measurement, and blank correction protocols.…”
Section: Methodsmentioning
confidence: 99%
“…All samples were prepared at the University of Vermont Cosmogenic Isotope Laboratory facilities following standard lab protocols [e.g., Corbett et al ., ]. Sample 26 Al/ 27 Al and 10 Be/ 9 Be ratios were measured on the Scottish Universities Environmental Research Centre accelerator mass spectrometry (AMS) laboratory in East Kilbride, Scotland [ Xu et al ., ]. The supporting information provides a detailed description of sample preparation, AMS measurement, and blank correction protocols.…”
Section: Methodsmentioning
confidence: 99%
“…Samples CS‐11, CS‐12, and CS‐17 and replicates of samples CS‐14, CS‐24, and CS‐30 were processed at the Scottish Universities Environmental Research Centre (SUERC) (http://www.gla.ac.uk/suerc/index.html) in East Kilbride, Scotland following procedures based on methods modified from Kohl and Nishiizumi () and Child et al (), at the GU‐SUERC Cosmogenic Isotope Laboratory. The 10 Be isolated in Scotland was measured at the SUERC Accelerator Mass Spectrometry Laboratory (Xu et al , ). Blank correction was done on the basis of one blank processed with these samples.…”
Section: Methodsmentioning
confidence: 99%
“…Thirteen boulders were 118 located in the clay-rich diamict unit and 15 were located in the sandy diamict unit ( Universities Environmental Research Centre (Xu et al, 2015). Measured sample ratios for 137 10 Be/ 9 Be (see supplemental data) are 6.6·10 -14 to 5.6·10 -13 (average analytic uncertainty 2.8 ± 0.5%, 1SD, n = 28).…”