2010
DOI: 10.1007/s00259-010-1526-x
|View full text |Cite
|
Sign up to set email alerts
|

Dedicated cardiac cameras: a new option for nuclear myocardial perfusion imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
15
0
3

Year Published

2012
2012
2015
2015

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(18 citation statements)
references
References 17 publications
0
15
0
3
Order By: Relevance
“…High liver radioactivity accumulation may interfere with visualization of the inferior wall of the heart using the standard SPECT cameras. For ultra-fast cardiac SPECT cameras, it is possible to position the patient upright during image acquisition, which would be helpful in minimizing the interference from the liver radioactivity because liver tends to drop downward in this position, allowing better separation of the cardiac and hepatic radioactivity [9,51,52]. As a result of their fast heart washout and prolonged liver radioactivity accumulation, we believe that 99m Tc-Teboroxime and 99m Tc-Teboroxime(N 3 ) are better suited for early image acquisition with ultra-fast cardiac SPECT cameras.…”
Section: Discussionmentioning
confidence: 99%
“…High liver radioactivity accumulation may interfere with visualization of the inferior wall of the heart using the standard SPECT cameras. For ultra-fast cardiac SPECT cameras, it is possible to position the patient upright during image acquisition, which would be helpful in minimizing the interference from the liver radioactivity because liver tends to drop downward in this position, allowing better separation of the cardiac and hepatic radioactivity [9,51,52]. As a result of their fast heart washout and prolonged liver radioactivity accumulation, we believe that 99m Tc-Teboroxime and 99m Tc-Teboroxime(N 3 ) are better suited for early image acquisition with ultra-fast cardiac SPECT cameras.…”
Section: Discussionmentioning
confidence: 99%
“…These improved systems enhance the sensitivity of count detection and thereby enable recording times or tracer doses to be reduced, a property that has highly favorable consequences on patient comfort and radiation exposure (1)(2)(3)(4). This enhancement is based mainly on acquisitions that are heart-centric but obtained with very different technologies: first, for the IQÁSPECT system (Siemens Medical Solutions (5-8)), an Anger camera equipped with collimators convergent on the image center (astigmatic collimators); second, for the DSPECT system (Spectrum Dynamics (9-13)), mobile columns of CZT detectors with wide parallel-hole collimators; and third, for the Discovery NM 530c system (GE Healthcare (14)(15)(16)(17)(18)(19)(20)(21)), fixed CZT detectors with multipinhole collimators.…”
mentioning
confidence: 99%
“…Cependant, c'est très certainement l'arrivée de caméras à semi-conducteurs CZT qui constitue la plus importante évolution technologique [21][22][23][24][25][26]. En comparaison aux caméras conventionnelles à scintillation, la sensibilité de détection de ces caméras CZT (qui représente le pourcentage de l'activité myocardique pouvant être détectée) est augmentée d'un facteur 6 à 10.…”
Section: Confort Et Sécurité Des Patientsunclassified
“…En comparaison aux caméras conventionnelles à scintillation, la sensibilité de détection de ces caméras CZT (qui représente le pourcentage de l'activité myocardique pouvant être détectée) est augmentée d'un facteur 6 à 10. Ceci permet de diminuer de manière encore plus drastique les activités injectées ainsi que les temps d'enregistrement [21][22][23][24]. Dans ces conditions, les doses absorbées par les patients peuvent être très faibles : de l'ordre de 3 mSv pour une séquence d'examen eff ortrepos réalisée avec un traceur marqué par le technétium-99m (Sestamibi ou Té-trofosmine), voire 1 mSv seulement si l'acquisition d'eff ort est normale et qu'il n'y a pas besoin d'eff ectuer une deuxième acquisition au repos [24].…”
Section: Confort Et Sécurité Des Patientsunclassified