Abstract: Purpose:To report the safety and the effectiveness of deep sclerectomy (DS) with a new nonabsorbable uveoscleral hema implant (Esnoper-Clip) designed to increase trabecular and uveoscleral outflow and to achieve higher intrascleral blebs.Materials and Methods:Twenty-seven eyes of 27 patients with open-angle glaucoma, who underwent DS with an Esnoper-Clip implant, were included in this study. All patients were followed up after 12 months.Results:A significant decrease in intraocular pressure was observed after … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

3
11
1
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(16 citation statements)
references
References 12 publications
3
11
1
1
Order By: Relevance
“…[5] Sanchez et al 1996. [6] Loscos J et al [7] Loscos-Arenas J et al [8] Greifner G et al [9] and most others indicate that the preoperative IOP taken for our study falls in the same range as that taken in other similar studies. Also the average age range in our study vs similar studies and within the three groups in our study are statistically insignificant.…”
Section: Resultssupporting
confidence: 63%
“…[5] Sanchez et al 1996. [6] Loscos J et al [7] Loscos-Arenas J et al [8] Greifner G et al [9] and most others indicate that the preoperative IOP taken for our study falls in the same range as that taken in other similar studies. Also the average age range in our study vs similar studies and within the three groups in our study are statistically insignificant.…”
Section: Resultssupporting
confidence: 63%
“… 33 , 47 , 48 This deficiency could be resolved by using materials with better modulation of biological responses, inducing minimal tissue reaction and scarring, especially in the suprachoroidal region. 47 According to Loscos-Arenas et al, 31 another important factor in the success rate for this surgery is implant design. Thus, the avoidance of implants that induce secondary fibrosis or TDM obstruction due to device displacement over the TDM is recommended.…”
Section: Discussionmentioning
confidence: 99%
“…A related nonabsorbable drainage device specially designed for supraciliary implantation is the foldable HEMA implant Esnoper Clip (AJL Ophthalmic). It was first implanted by Dr Loscos-Arenas at the Hospital Germans Trias i Pujol, Barcelona, Spain in 2011 31,32. This newer implant is equipped with 2 plates of which one is placed on the scleral bed and the other in the supraciliary space.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…36 Otro implante no reabsorbible de material acrílico con 2-hidroxietilmetacrilato (HEMA) ha sido desarrollado el ESNOPER (Esnoper, AJL Ophthalmics SA, Miñano, Alava, España) 36 que ha evolucionado o modificado su estructura en dos modelos ESNOPER-V2000 39,40 y el otro ESNO-PER-Clip. 40,41 Otro tipo es el implante reabsorbible de colágeno OLOGEN (Aeon Astron, Europa, Países Bajos) es un implante tridimensional de matriz de colágeno-GAP específicamente diseñado para promover la curación de la herida con la mínima respuesta de cicatrización. 42,43 Los tipos y características de los implantes de aplicación en la EPNP se describen en el anexo 2.…”
Section: Cirugia No Perforante Del Glaucomaunclassified