2020
DOI: 10.1016/j.jmrt.2020.07.090
|View full text |Cite
|
Sign up to set email alerts
|

Deformation and microstructural evolution of ultrafine- and fine-grained OFHC Cu during dynamic tensile extrusion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
18
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(19 citation statements)
references
References 28 publications
0
18
1
Order By: Relevance
“…On the contrary, it was recently reported that the DTE ductility increases as the grain size increases for ultrafine-grained (UFG, d < ~1 µm) and fine-grained (FG, ~1 µm < d < ~10 µm) Cu, which are manufactured by equal-channel angular pressing (ECAP); this is clearly an opposite trend compared with that observed for CG Cu [9]. During DTE deformation, the higher energy state and temperature increment of the UFG Cu can induce the occurrence of meta-dynamic recrystallization (mDRX) faster in comparison to the FG Cu and leads to a decrease in the DTE ductility [9]. Hence, it is revealed that the DTE ductility of the FG Cu can increase through a reduction in the residual stress and retardation of the mDRX.…”
Section: Introductionmentioning
confidence: 85%
See 4 more Smart Citations
“…On the contrary, it was recently reported that the DTE ductility increases as the grain size increases for ultrafine-grained (UFG, d < ~1 µm) and fine-grained (FG, ~1 µm < d < ~10 µm) Cu, which are manufactured by equal-channel angular pressing (ECAP); this is clearly an opposite trend compared with that observed for CG Cu [9]. During DTE deformation, the higher energy state and temperature increment of the UFG Cu can induce the occurrence of meta-dynamic recrystallization (mDRX) faster in comparison to the FG Cu and leads to a decrease in the DTE ductility [9]. Hence, it is revealed that the DTE ductility of the FG Cu can increase through a reduction in the residual stress and retardation of the mDRX.…”
Section: Introductionmentioning
confidence: 85%
“…Three DTE tests were conducted for each FG Cu specimen under identical DTE conditions. All fragments were softly recovered, weighed, and compared to the initial projectile weight to ensure the complete recovery [9]. DTE projectiles with a diameter of 7.62 mm were machined from FGM and FGH Cu specimens.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations