2018
DOI: 10.12669/pjms.342.14491
|View full text |Cite
|
Sign up to set email alerts
|

Degree of conversion and depth of cure of Ivocerin containing photo-polymerized resin luting cement in comparison to conventional luting agents

Abstract: Objective:To evaluate the degree of conversion (DC) and depth (extent) of cure of four resin cements (Variolink E, Calibra, NX3 and Variolink N) using Fourier transform infrared (FTIR) and Vickers Micro hardness (MH).Methods:Ten disks (1mmx2mm) of each resin cement were light cured through a ceramic disk for 40 seconds prior to assessment. The ATR spectra of the uncured resin were collected in absorbance mode from 16 scans at 4 wave number resolutions. Degree of conversion was calculated by estimating the chan… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
34
0

Year Published

2020
2020
2025
2025

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 27 publications
(35 citation statements)
references
References 21 publications
1
34
0
Order By: Relevance
“…35 The low DC observed for Variolink-N and Calibra compared to Variolink-E and NX3 may also be associated with the instability of these dual cure cements due to the presence of tertiary amines and benzoyl peroxide as initiators. 15,36 To compare the color stability of the four luting cements in the present study, spectrophotometry with the CIE L* a* b* system and a color difference formula was employed. 27,37 Currently, the CIE system is the most reproducible and comparable color measuring system.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…35 The low DC observed for Variolink-N and Calibra compared to Variolink-E and NX3 may also be associated with the instability of these dual cure cements due to the presence of tertiary amines and benzoyl peroxide as initiators. 15,36 To compare the color stability of the four luting cements in the present study, spectrophotometry with the CIE L* a* b* system and a color difference formula was employed. 27,37 Currently, the CIE system is the most reproducible and comparable color measuring system.…”
Section: Discussionmentioning
confidence: 99%
“…The DC methodology used was adopted from previous studies. 8,15 Resin cement samples were placed into vinyl molds (thickness, 1 mm; inner diameter, 2 mm). Mylar strips (DuPont Mylar 0.002 gauge/60 mm thick) were used to inhibit oxygen polymerization and facilitated placement of the ceramic discs prior to photo-polymerization.…”
Section: DCmentioning
confidence: 99%
See 3 more Smart Citations