2021
DOI: 10.1016/j.xops.2021.100058
|View full text |Cite
|
Sign up to set email alerts
|

Delineating Corneal Elastic Anisotropy in a Porcine Model Using Noncontact OCT Elastography and Ex Vivo Mechanical Tests

Abstract: Purpose: To compare noncontact acoustic microtapping (AmT) OCT elastography (OCE) with destructive mechanical tests to confirm corneal elastic anisotropy.Design: Ex vivo laboratory study with noncontact AmT-OCE followed by mechanical rheometry and extensometry.Participants: Inflated cornea of whole-globe porcine eyes (n ¼ 9). Methods: A noncontact AmT transducer was used to launch propagating mechanical waves in the cornea that were imaged with phase-sensitive OCT at physiologically relevant controlled pressur… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 15 publications
(13 citation statements)
references
References 35 publications
0
13
0
Order By: Relevance
“…To generate elastic waves without any contact to the skin surface, we applied an excitation push with acoustic micro-tapping (AμT), a technique using a cylindrically focused, air-coupled ultrasound transducer to induce a localized radiation force at the tissue surface 18 21 , 64 , 65 . The AμT transducer effectively applied a line load to the surface over a wide region relative to the propagation distance of interest, resulting in approximately planar elastic waves (normal to the OCT imaging plane).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…To generate elastic waves without any contact to the skin surface, we applied an excitation push with acoustic micro-tapping (AμT), a technique using a cylindrically focused, air-coupled ultrasound transducer to induce a localized radiation force at the tissue surface 18 21 , 64 , 65 . The AμT transducer effectively applied a line load to the surface over a wide region relative to the propagation distance of interest, resulting in approximately planar elastic waves (normal to the OCT imaging plane).…”
Section: Methodsmentioning
confidence: 99%
“…Recently, we developed a model of a nearly incompressible transversely isotropic (NITI) medium 20 , opening the way for quantitative evaluation of anisotropic elastic properties in biological tissues. We used the NITI model to quantify corneal elasticity and justified it by direct comparison with mechanical tests 21 .…”
Section: Introductionmentioning
confidence: 99%
“…Notably, AµT-OCE is the only reported method that can accurately measure both 𝜇 (and therefore 𝐸 = 3𝜇) and 𝐺 simultaneously in a non-invasive, non-contact manner. 41 This is critical for in vivo studies of human corneal physiology and pathophysiology.…”
Section: Discussionmentioning
confidence: 99%
“…Accounting for cornea collagen microstructure consisting of thin layers (lamellas) primarily oriented in-plane of the stroma, the macroscopic stress-strain relationship in the cornea for small deformations can be described by Hook's law in a NITI material and takes the form (in Voigt notation) 41 :…”
Section: Nearly Incompressible Transverse Isotropic (Niti) Model Of C...mentioning
confidence: 99%
See 1 more Smart Citation