Dental implants displaced into the mandibular corpus: clinical note

Abstract: Purpose: Implant migration into the mandibular corpus is a complication reported few times in literature. The aim of study was to describe the clinical characteristics of patients who developed implant displacement into the mandibular corpus, to identify potential risk factors, and to gather information on prevention and treatment of this complication. Methods: We report three cases of implants displaced into the mandibular corpus laterally of mental nerve. Two implants were removed by screwdriver, in only one… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 8 publications
0
3
0
Order By: Relevance
“…Few of these reports provide a detailed description of the circumstances under which the implant body became displaced. In the reports that do include such a description, however, the cause indicated is sudden loss of torque during insertion 3) , or displacement during cover screw setting, with a subsequent attempt at removal pushing the implant even deeper in 12,14) . These include two specific cases in which the initially inserted implant body was displaced into the mandibular bone and lost to sight.…”
Section: Factors Causing Implant Body Displacement In Mandiblementioning
confidence: 99%
See 1 more Smart Citation
“…Few of these reports provide a detailed description of the circumstances under which the implant body became displaced. In the reports that do include such a description, however, the cause indicated is sudden loss of torque during insertion 3) , or displacement during cover screw setting, with a subsequent attempt at removal pushing the implant even deeper in 12,14) . These include two specific cases in which the initially inserted implant body was displaced into the mandibular bone and lost to sight.…”
Section: Factors Causing Implant Body Displacement In Mandiblementioning
confidence: 99%
“…The operators mistakenly believed that it had been sucked up into the suction tube, however, and therefore inserted a second implant body 1,11) . Factors causing an implant body to become displaced within the mandibular bone include bone quality and osteoporosis or other bone diseases, mistaken preoperative X-ray evaluation, and inadequate skills on the part of the operator 6,9,10,12) . In most cases, it is the cortical bone of the alveolar crest that is mainly responsible for initial implant fixation.…”
Section: Factors Causing Implant Body Displacement In Mandiblementioning
confidence: 99%
“…In the case of mandibular displacement, there is a displacement to the bone marrow defect of mandibular body though it is not common [5][6][7][8][9][10][11][12][13][14][15]…”
Section: Introductionmentioning