2021
DOI: 10.17219/acem/134875
|View full text |Cite
|
Sign up to set email alerts
|

Dentists can provide reliable shear wave elastography measurements of the stiffness of masseter muscles: A possible scenario for a faster diagnostic process

Abstract: Dentists can provide reliable shear wave elastography measurements of the stiffness of masseter muscles: A possible scenario for a faster diagnostic process.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 7 publications
(20 citation statements)
references
References 31 publications
0
19
1
Order By: Relevance
“…We analyzed data obtained from 140 healthy volunteers (74 men and 66 women) with a median age of 50 years (95% confidence interval (CI): 45.9-55). For women, the median The stiffness of the masseter muscle was measured with the Aixplorer Ultimate device (SuperSonic Imagine, Aix-en-Provence, France) using a high-frequency linear probe SL 18-5 (5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18). The obtained measurements were validated using the elasticity QA Phantom model 049A (Computerized Imaging Reference Systems, Inc, Norfolk, VA, USA).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…We analyzed data obtained from 140 healthy volunteers (74 men and 66 women) with a median age of 50 years (95% confidence interval (CI): 45.9-55). For women, the median The stiffness of the masseter muscle was measured with the Aixplorer Ultimate device (SuperSonic Imagine, Aix-en-Provence, France) using a high-frequency linear probe SL 18-5 (5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18). The obtained measurements were validated using the elasticity QA Phantom model 049A (Computerized Imaging Reference Systems, Inc, Norfolk, VA, USA).…”
Section: Resultsmentioning
confidence: 99%
“…Olchowy et al assessed the reliability of SWE measurements for the masseter muscle using intraclass correlation coefficients and observed excellent results [12]. Other researchers also proved this method to be reliable for different muscles [25][26][27].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Measurements were validated using an elasticity QA Phantom model 049A (Computerized Imaging Reference Systems, Inc, Norfolk, VA, USA). Inter-and intraobserver agreements between the stiffness measurements of the masseter muscle performed using the Aixplorer Ultimate device were rated excellent and confirmed diagnostic accuracy of this method [29]; however, in this study, the calculation of the intraobserver agreement was not included.…”
Section: Methodsmentioning
confidence: 58%
“…Another advantage of shear-wave elastography is its ability to identify trigger points and help to make a diagnosis of myofascial pain syndrome [28]. Among other advantages of shear-wave elastography, it is its simplicity that allows dentists and other specialists to monitor disease response to treatment [29].…”
Section: Introductionmentioning
confidence: 99%