2020
DOI: 10.1016/j.ijleo.2020.165210
|View full text |Cite
|
Sign up to set email alerts
|

Dependence of thermal diffusivity on nanoparticle shape deduced through thermal lens technique taking ZnO nanoparticles and nanorods as inclusions in homogeneous dye solution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 21 publications
0
5
0
Order By: Relevance
“…On the contrary, TLS is highly sensitive to rather slight changes in the sample composition and also requires minimal sample preparation [ 42 , 43 ]. Emphasis of TLS application in this area is placed on the accurate calculation of thermophysical properties of nanofluids [ 36 , 43 , 44 , 45 , 46 ], biodiesel [ 47 , 48 ] solid multicomponent systems [ 49 ], nanoparticles [ 50 , 51 , 52 ], quantum dots [ 53 ], glasses [ 54 , 55 , 56 ], and semiconductors [ 57 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…On the contrary, TLS is highly sensitive to rather slight changes in the sample composition and also requires minimal sample preparation [ 42 , 43 ]. Emphasis of TLS application in this area is placed on the accurate calculation of thermophysical properties of nanofluids [ 36 , 43 , 44 , 45 , 46 ], biodiesel [ 47 , 48 ] solid multicomponent systems [ 49 ], nanoparticles [ 50 , 51 , 52 ], quantum dots [ 53 ], glasses [ 54 , 55 , 56 ], and semiconductors [ 57 ].…”
Section: Introductionmentioning
confidence: 99%
“…In the practice of thermal-lens measurements, the issues of trueness are given less attention, and the available results are non-systemic [ 63 , 64 ]. In applied research, the main emphasis is on the precision of the results, improperly considering this as the only factor that governs the accuracy [ 50 , 53 , 65 ]. Some aspects of the trueness of thermal-lens measurements are considered in the context of optimizing methods for a particular analyte (and, as a rule, only in relation to the signal amplitude), within which an original setup is designed, and its operation parameters are optimized [ 66 , 67 ].…”
Section: Introductionmentioning
confidence: 99%
“…Photothermal Analysis by Dual Beam Method. Thermal lens spectroscopy was employed to estimate the thermal diffusivity of the synthesized sample as explained in reports [15]. The nanofluids of synthesized samples were prepared in water with a concentration of 1gL -1 .…”
Section: Synthesismentioning
confidence: 99%
“…The mixture was then centrifuged at 3000 rpm for 30 minutes and the supernatant was removed and the precipitate was cooled to room temperature for 2−4 hours and then washed several times to remove the organic impurities and other unreacted compounds. Later, the precipitate was ground using an agate mortar and pestle for making nanoparticles [8].…”
Section: Preparation Techniquementioning
confidence: 99%