2003
DOI: 10.21236/ada417176
|View full text |Cite
|
Sign up to set email alerts
|

DEPSCoR 99 Percutaneous Absorption, Skin Biophysics and Dermatotoxicity from JP-8 Jet Fuel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
0
2

Year Published

2016
2016
2016
2016

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 38 publications
0
0
2
Order By: Relevance
“…Even though no noticeable change was observed in this work, the observation in a previous report clearly shows that the tilting angle of AgNRs decreases as the substrate temperature is lowered [25]. The tilting angle of the AgNRs, fabricated by an e-beam evaporator with 86° of deposition angle, was observed to decrease by ~2° when the substrate temperature was lowered from room temperature to 140 K [25]. Our observation of no noticeable variation of the tilting angle in the whole temperature range, 10-70 °C can be interpreted as the variation of the tilting angle was too small to be observed clearly.…”
Section: Mechanism Of Agnr Array Formation and The Role Of Substrate contrasting
confidence: 79%
See 1 more Smart Citation
“…Even though no noticeable change was observed in this work, the observation in a previous report clearly shows that the tilting angle of AgNRs decreases as the substrate temperature is lowered [25]. The tilting angle of the AgNRs, fabricated by an e-beam evaporator with 86° of deposition angle, was observed to decrease by ~2° when the substrate temperature was lowered from room temperature to 140 K [25]. Our observation of no noticeable variation of the tilting angle in the whole temperature range, 10-70 °C can be interpreted as the variation of the tilting angle was too small to be observed clearly.…”
Section: Mechanism Of Agnr Array Formation and The Role Of Substrate contrasting
confidence: 79%
“…The tilting angle, β , observed in their AgNR samples did not show any of the proposed relationships with the impinging angle, θ , i.e., neither the tangent rule, β t = arctan In addition to the relatively large tilting angle of AgNRs, we also find the influence of substrate temperature on the tilting angle. Even though no noticeable change was observed in this work, the observation in a previous report clearly shows that the tilting angle of AgNRs decreases as the substrate temperature is lowered [25]. The tilting angle of the AgNRs, fabricated by an e-beam evaporator with 86° of deposition angle, was observed to decrease by ~2° when the substrate temperature was lowered from room temperature to 140 K [25].…”
Section: Mechanism Of Agnr Array Formation and The Role Of Substrate contrasting
confidence: 66%