2019
DOI: 10.1080/00295639.2019.1654327
|View full text |Cite
|
Sign up to set email alerts
|

Derivation of the Two-Exponential Probability Density Function for Rossi-Alpha Measurements of Reflected Assemblies and Validation for the Special Case of Shielded Measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2
1

Relationship

2
6

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 8 publications
0
6
0
Order By: Relevance
“…Traditionally, the histogram is fit with a single-exponential-plus-constant model [4]. Recent work has developed a double-exponential-plus-constant-model [5] that is more suitable than the single exponential model for measurements of reflected assemblies. The two-exponential model estimates a second parameter: ctd , which describes the mean time a neutron spends in the reflector prior to detection.…”
Section: The Rossi-alpha Methodsmentioning
confidence: 99%
“…Traditionally, the histogram is fit with a single-exponential-plus-constant model [4]. Recent work has developed a double-exponential-plus-constant-model [5] that is more suitable than the single exponential model for measurements of reflected assemblies. The two-exponential model estimates a second parameter: ctd , which describes the mean time a neutron spends in the reflector prior to detection.…”
Section: The Rossi-alpha Methodsmentioning
confidence: 99%
“…The method is based on the nonrandom distribution between neutron detection times: the population of correlated prompt neutrons (those from the same fission chain seed) decays exponentially as fission chains extinguish [15]. Experimental results showed that the decay is modeled better by a two-exponential function than a one-exponential function when the assembly of fissile material is reflected [16,6], the model was theoretically derived from two-region point kinetics [17,18,11], and validated with a combination of experiments and simulations [12,19]. The two-exponential Rossi-alpha probability density function for reflected assemblies p R (τ) is given by…”
Section: Rossi-alpha Methodsmentioning
confidence: 99%
“…The first order uncertainty in α is determined by propagating the uncertainty in the fit parameters through Eqn. (11) via…”
Section: Uncertainty Propagation From Fit Parameters To αmentioning
confidence: 99%
See 1 more Smart Citation
“…The scintillator systems are primarily used for gamma-ray die-off analysis 107 while the neutron detectors utilize neutron noise methods. 108,109 As shown in Fig. 19c, some measurements were performed outside the DAF.…”
Section: Ivd Neutron Diagnosed Subcritical Experimentsmentioning
confidence: 99%