2004
DOI: 10.1016/j.talanta.2004.03.060
|View full text |Cite
|
Sign up to set email alerts
|

Derivative spectrophotometry?recent applications and directions of developments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
75
0
8

Year Published

2007
2007
2014
2014

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 149 publications
(84 citation statements)
references
References 214 publications
1
75
0
8
Order By: Relevance
“…According to Karpinska, the main disadvantage of the derivative method is the low reproducibility. 23 Besides, it is necessary have caution with the specificity, mainly for steroidal drugs, with the chemical structures have similar groups that can interfere with the analysis. This point justifies the importance of the development and validation of methods following the principles described by the guidelines.…”
Section: Resultsmentioning
confidence: 99%
“…According to Karpinska, the main disadvantage of the derivative method is the low reproducibility. 23 Besides, it is necessary have caution with the specificity, mainly for steroidal drugs, with the chemical structures have similar groups that can interfere with the analysis. This point justifies the importance of the development and validation of methods following the principles described by the guidelines.…”
Section: Resultsmentioning
confidence: 99%
“…In this work, the derivative spectrophotometry technique was used, which in this moment is used when the spectral bands are overlapped. On the other hand, different rewiers, about methods that used this technique and its different modalities have been reported [17][18][19][20][21] . On the other hands the past 20 years, various studies show that these drugs represent a new class of environmental contaminants.…”
Section: Introductionmentioning
confidence: 99%
“…Several spectrophotometric methods, such as derivative spectrophotometry, [1][2][3][4][5] ratio spectra derivative method, 6 ratio spectra derivative-zero crossing method, 7-9 DDRS-DS method [10][11][12][13][14] and double divisor-ratio spectra derivative-zero crossing method 15 have been reported in the literature and applied for ternary and quaternary mixtures. However, it was observed that the derivative spectrophotometry and ratio spectra derivative method provide a good analytical resolution of binary mixtures but these two methods do not give always desirable results for the analysis of ternary and quaternary mixtures.…”
Section: Introductionmentioning
confidence: 99%