2014
DOI: 10.5545/sv-jme.2014.1688
|View full text |Cite
|
Sign up to set email alerts
|

Design and Research for the Water Low-pressure Large-flow Pilot-operated Solenoid Valve

Abstract: The basic requirements of the valve-control coupling for control valves are quick response, high flow capacity, and anti-blocking ability. In this article, a pure water hydraulic test-bed is built, and the pressure distribution characteristics between the throttle nozzle and the pilot valve, as well as the flow characteristics in the throttle orifice are researched. Following that, the water medium low pressure large-flow pilot operated solenoid valve is designed. The influences of throttle nozzles' diameter a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 5 publications
0
5
0
Order By: Relevance
“…Further researches were conducted to optimize the design parameters for a two-stage, 2-way hydraulic valve for water hydraulics [124] and for construction machinery applications [125]. Another was performed to optimize the controller of the Pilot valve alongside the main valve [126].…”
Section: Pressure Control Units In Heavy Duty Automatic Transmissionmentioning
confidence: 99%
“…Further researches were conducted to optimize the design parameters for a two-stage, 2-way hydraulic valve for water hydraulics [124] and for construction machinery applications [125]. Another was performed to optimize the controller of the Pilot valve alongside the main valve [126].…”
Section: Pressure Control Units In Heavy Duty Automatic Transmissionmentioning
confidence: 99%
“…On energisation of the solenoid coil, [1] the pilot valve opens due to the magnetic force of attraction between the solenoid plunger (which is the integral part of the pilot valve poppet) and armature. Since, the pilot valve port is small, the required load and thereby, the plunger diameter, number of coil ampere turns and power are less compared to a direct acting solenoid valve with a port equal to that of main valve .…”
Section: Working Principlementioning
confidence: 99%
“…Solver) and the block for definition of the oil/ undissolved air mixture (i.e. Oil-Air) [28]. The steel pipe P (see Fig.…”
Section: Mathematical Modelmentioning