Design of the National Ignition Facility diagnostic instrument manipulator

Abstract: The diagnostic instrument manipulator ͑DIM͒ provides a diagnostic platform to insert and retract a variety of instruments into and out of the National Ignition Facility target chamber. The DIM is a two-stage telescoping system, designed to fit on any of the DIM designated diagnostic ports on the target chamber, and will provide precision radial positioning, pointing, and alignment-to-target capability. The DIM provides a standard set of utilities, and cables to support the operation of instruments that require… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2003
2003
2015
2015

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(11 citation statements)
references
References 2 publications
0
11
0
Order By: Relevance
“…In ada) fournier2@llnl.gov b) jfisher@gray-research.com c) cdavidnewlander@yahoo.com d) Phillip.Jenkins@nrl.navy.mil dition, there are three diagnostic instrument manipulators (DIMs) 9 at set locations on the target chamber (two on the chamber's equator, one at the chamber's upper pole) that allow for servicing or change of a diagnostic during a shot cycle.…”
Section: Requirements and Design Considerationsmentioning
confidence: 99%
“…In ada) fournier2@llnl.gov b) jfisher@gray-research.com c) cdavidnewlander@yahoo.com d) Phillip.Jenkins@nrl.navy.mil dition, there are three diagnostic instrument manipulators (DIMs) 9 at set locations on the target chamber (two on the chamber's equator, one at the chamber's upper pole) that allow for servicing or change of a diagnostic during a shot cycle.…”
Section: Requirements and Design Considerationsmentioning
confidence: 99%
“…Between 1 and 4 spectrometers are fielded on the polar (0-0) and equatorial (90-78) diagnostic manipulators (DIMs) 33 . Each WRF provides a complete spectral measurement of the D 3 He protons, from which yield, ρR, and R cm are inferred.…”
Section: Nif Experimentsmentioning
confidence: 99%
“…0° radial access would also be desirable for neutron diagnostics. A retractable diagnostic insertion manipulator (DIM) [87] of some type would be required for radial diagnostic operation in this arrangement. There is also a radial access requirement for a cryogenic system to insert frozen DT fuel capsules into the secondary hohlraum.…”
Section: Iv19 Conceptual Design Study For Zr Double-sideddrive Confmentioning
confidence: 99%
“…The Diagnostic Insertion Manipulator (DIM) is a device for inserting and accurately positioning diagnostic packages into large spherical laser target chambers that require retraction of the instruments for chamber interior cleaning and maintenance [87]. DIMs with common design and in several sizes have been developed for use on target chambers at the Nova, OMEGA, and NIF facilities (Fig.…”
Section: Iv5 Diagnostic Insertion Manipulators (Dims)mentioning
confidence: 99%