2018
DOI: 10.1155/2018/3908610
|View full text |Cite
|
Sign up to set email alerts
|

Design Optimization of HANARO Irradiation Capsule for Long-Term Irradiation Testing

Abstract: As HANARO has been recently required to support new R&D relevant to future nuclear systems requiring much higher neutron fluence, two types of bottom rod tip of the capsule were preliminarily prepared. The first one is a conventional design made of STS304 and welded using a tungsten inert gas (TIG) welding method. The other is a new design made of STS316L and welded using electron beam (EB) welding to strengthen the fatigue property of the rod tip. During the out-pile testing, they failed after 40 and 203 days… Show more