Detachment of an Annular Patch Following the Manougian Procedure

Abstract: Detachment of the prosthetic patch material is a rare complication in the early postoperative period following a Manougian's procedure. We present the case of a young adult presenting with significant mitral regurgitation associated with a defect in the anterior mitral leaflet early after an uneventful Manougian's procedure performed with a prosthetic patch.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(10 citation statements)
references
References 6 publications
0
10
0
Order By: Relevance
“…Across all studies, a total of patients underwent SAVR. The type of prosthesis used differed between the included studies, with 13 3,20,21,[23][24][25][26]30,33,39,41,44,47 implanting a bioprosthesis, 8 15,16,19,29,34,35,40,42 implanting a mechanical prosthesis, and 3 1,36,37 implanting mechanical and biological protheses; 12 studies 22,27,28,31,32,38,43,45,46,[48][49][50] did not specify prosthesis type. The size of the implanted prosthesis ranged from 17 mm 45 to 27 mm 20,24 ; however, 14 studies 1,[27][28][29]31,32,36,37,43,[46][47]…”
Section: Study Characteristicsmentioning
confidence: 99%
See 4 more Smart Citations
“…Across all studies, a total of patients underwent SAVR. The type of prosthesis used differed between the included studies, with 13 3,20,21,[23][24][25][26]30,33,39,41,44,47 implanting a bioprosthesis, 8 15,16,19,29,34,35,40,42 implanting a mechanical prosthesis, and 3 1,36,37 implanting mechanical and biological protheses; 12 studies 22,27,28,31,32,38,43,45,46,[48][49][50] did not specify prosthesis type. The size of the implanted prosthesis ranged from 17 mm 45 to 27 mm 20,24 ; however, 14 studies 1,[27][28][29]31,32,36,37,43,[46][47]…”
Section: Study Characteristicsmentioning
confidence: 99%
“…Of the 207 reported cases of new or worsened MR, 138 patients presented with a worsened severity of MR 1,3,20,[25][26][27]30,32,33,[36][37][38]48 after SAVR, for a reported prevalence of 66.7%. Additionally, 16 patients who received SAVR developed new MR, 15,16,19,21,23,24,34,38,39,44,46,49,50 for a reported prevalence of 7.7%. The remaining 53 cases 22,28,29,31,35,42,45 of reported new or worsened MR could not be specifically categorized due to lack of detail regarding the patients' preoperative status.…”
Section: Prevalence Of Reported New or Worsened Mrmentioning
confidence: 99%
See 3 more Smart Citations