2018
DOI: 10.3788/aos201838.1001005
|View full text |Cite
|
Sign up to set email alerts
|

Detection Method of Dissolved Oxygen Concentration in Water Based on Time-Domain Fluorescence Lifetime

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…In addition to improving the SNR and ensuring the transmission quality, the optical dissolved oxygen sensor can also use digital signal processing to calculate the dissolved oxygen concentration. Xu proposed a time-domain fluorescence lifetime-based method for dissolved oxygen detection [169]. Fluorescence was generated by periodic pulsed light excitation with a lifetime that was much longer than the fluorescence lifetime, fully ensuring that the fluorescence generated by the previous excitation completely died out before the fluorescence was generated by the next excitation.…”
Section: Intelligent Dissolved Oxygen Sensor Technologiesmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition to improving the SNR and ensuring the transmission quality, the optical dissolved oxygen sensor can also use digital signal processing to calculate the dissolved oxygen concentration. Xu proposed a time-domain fluorescence lifetime-based method for dissolved oxygen detection [169]. Fluorescence was generated by periodic pulsed light excitation with a lifetime that was much longer than the fluorescence lifetime, fully ensuring that the fluorescence generated by the previous excitation completely died out before the fluorescence was generated by the next excitation.…”
Section: Intelligent Dissolved Oxygen Sensor Technologiesmentioning
confidence: 99%
“…Xu designed a method to detect dissolved oxygen, which uses a microprocessor to control the LED to generate pulsed light signals to excite the fluorescence emission, which is amplified by an amplification circuit, and finally calculates the fluorescence lifetime by comparing the fluorescence intensity of two points to obtain the concentration of dissolved oxygen. This method integrates analog signal processing technology and digital signal processing technology, and has excellent detection performance [169]. Shu used the ATmega128 microcontroller as the core to design the hardware circuit of a working system, including the design of a polarization voltage generation circuit, signal acquisition circuit, temperature compensation circuit, and serial communication circuit [176].…”
Section: Intelligent Dissolved Oxygen Sensor Technologiesmentioning
confidence: 99%