2020
DOI: 10.1101/2020.05.22.111047
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Detection of a multi-disease biomarker in Saliva with Graphene Field Effect Transistors

Abstract: Human carbonic anhydrase 1 (CA1) has been suggested as a biomarker for identification of several diseases including cancers, pancreatitis, diabetes, and Sjogren's syndrome. However, the lack of a rapid, cheap, accurate, and easy-to-use quantification technique has prevented widespread utilization of CA1 for practical clinical applications. To this end, we present a label-free electronic biosensor for detection of CA1 utilizing highly sensitive graphene field effect transistors (G-FETs) as a transducer and spec… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
2
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 53 publications
1
2
0
Order By: Relevance
“…30 Liquid gated G-FET sensors significantly lower the required voltage (below 2 V) as well as keep the probes and analytes in their original size and conformation. Our prior work, as well as others 38,39 , show liquid gating is a reliable approach with less complex electronics required for backgated FET. In this work, we utilized our upgraded G-FET platform having on-chip coplanar Pt side gate electrodes which provides a miniaturized G-FET platform and allows upscaling of the number of devices on the same chip while measuring them simultaneously (see Figure 1).…”
Section: Resultssupporting
confidence: 52%
See 2 more Smart Citations
“…30 Liquid gated G-FET sensors significantly lower the required voltage (below 2 V) as well as keep the probes and analytes in their original size and conformation. Our prior work, as well as others 38,39 , show liquid gating is a reliable approach with less complex electronics required for backgated FET. In this work, we utilized our upgraded G-FET platform having on-chip coplanar Pt side gate electrodes which provides a miniaturized G-FET platform and allows upscaling of the number of devices on the same chip while measuring them simultaneously (see Figure 1).…”
Section: Resultssupporting
confidence: 52%
“…To obtain a resistance vs liquid gate voltage plot, the measurements were performed in 0.01x PBS to minimize the Debye screening effect. 38 Figure 3c shows the shift in Dirac voltage ( V D ) after successive functionalization with PBASE linker and NX-aptamers. Further shift in V D was observed upon incubation of NX target at concentrations of 1 nM and 10 nM while saturating when measured with 100 nM.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation