IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI) 2014
DOI: 10.1109/bhi.2014.6864462
|View full text |Cite
|
Sign up to set email alerts
|

Detection of artifacts in oscillometric pulsations signals

Abstract: A measurement of blood pressure is a basic diagnostic technique for examining of the cardiovascular system. There are a lot of methods for determination of the blood pressure, but an oscillometric measurement (investigation of oscillometric pulsations) is one of the most frequent methods used in modern electronic tonometers. The results given by oscillometric measurements are very dependent on the cleanness of the signal. The method is very sensitive for example for motion artifacts, which produce significant … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 8 publications
0
5
0
Order By: Relevance
“…Most of the existing artifact detection methods divide the pulse signal into multiple segments of 5∼10 seconds; extract statistical information such as mean, variance, and sample entropy of the segment; then analyze these statistical features; and use the threshold method to distinguish whether the pulse segment is segmented. [9,10,14,[15][16][17].…”
Section: Detection and Removal Of Artifactsmentioning
confidence: 99%
See 3 more Smart Citations
“…Most of the existing artifact detection methods divide the pulse signal into multiple segments of 5∼10 seconds; extract statistical information such as mean, variance, and sample entropy of the segment; then analyze these statistical features; and use the threshold method to distinguish whether the pulse segment is segmented. [9,10,14,[15][16][17].…”
Section: Detection and Removal Of Artifactsmentioning
confidence: 99%
“…In 1994, Qian Weili and others of Lanzhou University proposed to use the Gaussian function to synthesize pulse waves and establish a pulse signal model [9]. Many scholars have demonstrated the Gaussian function synthetic pulse wave, and the results show that the three Gaussian functions can e ectively describe the pulse waveform morphology [10,11].…”
Section: Algorithm Simulation and Comparisonmentioning
confidence: 99%
See 2 more Smart Citations
“…One way to measure the BP is through arterial tonometer [5,6]. The heart-to-beat waveform can be measured from arterial tonometer but is strongly subject to motion artifacts caused by high sensitivity, sensor placement and movement [7]. Cuff sphygmomanometer is the most standard non-invasive technique that is used to measure BP [8].…”
Section: Introductionmentioning
confidence: 99%