2009
DOI: 10.1016/j.snb.2009.04.047
|View full text |Cite
|
Sign up to set email alerts
|

Detection of nitrite using poly(3,4-ethylenedioxythiophene) modified SPCEs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
37
0

Year Published

2010
2010
2018
2018

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 88 publications
(37 citation statements)
references
References 29 publications
0
37
0
Order By: Relevance
“…The Levich plot is found to be linear which indicating that the electrocatalytic oxidation of DA at RDE is mass transport-limited. However, the plot did not pass through the origin suggesting that a kinetic limitation is involved in the electron transfer reaction.Therefore the oxidation of DA is involved mixed (surface and diffusion) process [32]. Figure 6 A shows that the currentÀtime (iÀt) response at MWCNT-NiTsPc/AGCE by the successive addition of DA concentration such as 10 mM, 50 mM and 100 mM.…”
Section: Rotating Disc Electrode Studiesmentioning
confidence: 99%
“…The Levich plot is found to be linear which indicating that the electrocatalytic oxidation of DA at RDE is mass transport-limited. However, the plot did not pass through the origin suggesting that a kinetic limitation is involved in the electron transfer reaction.Therefore the oxidation of DA is involved mixed (surface and diffusion) process [32]. Figure 6 A shows that the currentÀtime (iÀt) response at MWCNT-NiTsPc/AGCE by the successive addition of DA concentration such as 10 mM, 50 mM and 100 mM.…”
Section: Rotating Disc Electrode Studiesmentioning
confidence: 99%
“…We reported PEDOT-modified screen-printed electrode (SPE/ PEDOT) for determining cysteine [32]. Recently, Ho et al reported detection of nitrite at SPE/PEDOT [33].…”
Section: Introductionmentioning
confidence: 99%
“…The surface functionality of PEDOT tends to trap anionic analytes based on electrostatic attractions [30,32,33]. The hydrophobic nature of PEDOT film also facilitates accumulating neutral, nonelectrolytic organic analytes [31].…”
Section: Introductionmentioning
confidence: 99%
“…The PEDOT-modified electrodes have also been used for determining pesticides [7]. PEDOT-modified screen-printed carbon electrode is also used for the detection of nitrite [8]. Su and Cheng used the PEDOT-modified screen-printed electrode for the determination of cysteine [9].…”
Section: Introductionmentioning
confidence: 99%