2019
DOI: 10.1016/j.jenvman.2019.03.131
|View full text |Cite
|
Sign up to set email alerts
|

Determination and evaluation of kinetic parameters of activated sludge biomass from a sludge reduction system treating real sewage by respirometry testing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 19 publications
(12 citation statements)
references
References 33 publications
0
12
0
Order By: Relevance
“…The slope of the linear regression was used as a way of expressing Y obs. The relative sludge reduction was calculated using observed yield ratios obtained from identical systems operated in a conventional activated sludge manner with daily wastage of sludge (Karlikanovaite-Balikci and Yagci, 2019).…”
Section: Methodsmentioning
confidence: 99%
“…The slope of the linear regression was used as a way of expressing Y obs. The relative sludge reduction was calculated using observed yield ratios obtained from identical systems operated in a conventional activated sludge manner with daily wastage of sludge (Karlikanovaite-Balikci and Yagci, 2019).…”
Section: Methodsmentioning
confidence: 99%
“…There have been various configurations of OSA applications including the attachment of interchange bioreactor to the main conventional activated sludge (CAS) [21], [33], membrane (MBR) [14] or sequencing batch reactors (SBR) [19], [34] reactors presented in the literature. SBR-OSA configuration has advantages over the CAS-OSA or MBR-OSA applications due to the lower space requirement in the waterline due to the absence of the secondary settling and the intermittent sludge cycling.…”
Section: Concept Of Osa Processmentioning
confidence: 99%
“…The observed yield varied between 0.112 and 0.465 gTSS/gCOD, showing that the excess sludge reduction due to the insertion of the sludge holding tank was 49.6 ± 20.7% compared to the conventional CAS system. Apart from this, a recent study by Karlikanovaite-Balikci and Yagci [19] evaluated simultaneous sludge reduction and in an oxic-settlinganoxic (OSA) system fed with real domestic wastewater at different sludge ages. The greatest corresponding sludge reduction was achieved as 58% operated at an interchange ratio of 7.7% (1/13) in the OSA system.…”
Section: The Potential Of the Osa Process In Terms Of Observed Sludge Yieldmentioning
confidence: 99%