2005
DOI: 10.1016/j.aca.2004.10.016
|View full text |Cite
|
Sign up to set email alerts
|

Determination of cosmochemically volatile trace elements in chondritic meteorites by inductively coupled plasma mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2005
2005
2014
2014

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 25 publications
(12 citation statements)
references
References 26 publications
1
11
0
Order By: Relevance
“…In our previous attempts, we modified SPE membrane disks with suitable compounds for selective determination of chromium [18][19]36 and lead 21 . Meanwhile, other investigators have successfully utilized these sorbents for quantitative extraction and monitoring trace amounts of lead [22][23][24] , copper [25][26] , silver [28][29] , mercury [30][31] , cadmium 32 , palladium 33 , Ce 34 and UO 2 35 .…”
Section: Oriental Journal Of Chemistrymentioning
confidence: 99%
See 1 more Smart Citation
“…In our previous attempts, we modified SPE membrane disks with suitable compounds for selective determination of chromium [18][19]36 and lead 21 . Meanwhile, other investigators have successfully utilized these sorbents for quantitative extraction and monitoring trace amounts of lead [22][23][24] , copper [25][26] , silver [28][29] , mercury [30][31] , cadmium 32 , palladium 33 , Ce 34 and UO 2 35 .…”
Section: Oriental Journal Of Chemistrymentioning
confidence: 99%
“…GO [36] (15 mg) was stirred in 20 mL of oxalyl chloride at 80 °C for 24 h to activate the carboxylic units by forming the corresponding acyl chlorides. Then, the reaction mixture was evaporated to remove the excess oxalyl chloride and the brownish remaining solid (GO-COCl) was washed with anhydrous tetrahydrofuran (THF).…”
Section: Synthesis Of Go-h 2 Npmentioning
confidence: 99%
“…This 103.8 mg wholerock powdered sample was dissolved and analyzed by quadrupole ICPMS (PQ Excell, ThermoElectron Corporation, Waltham, MA, USA) using methodology and instrumentation described in Wolf et al (2005). For this work, calibration involved the standard addition method with internal standardization.…”
Section: Methodsmentioning
confidence: 99%
“…The analytical figures of merit of ICPMS rival that of RNAA and, because its high sample throughput capabilities facilitate the measurement of multiple blanks and application of time-dependent external drift corrections, ICPMS offers the possibility that it can supplant RNAA as the technique of choice for quantifying our suite of highly labile trace elements (cf. Wolf et al 2005), even in lunar samples.…”
Section: Introductionmentioning
confidence: 99%
“…However, these methods are laborious and are apt to carry a risk of contamination. A variety of methods have been proposed for the determination of thallium such as inductively coupled plasma (Miyazaki et al, 1992), inductively coupled plasma-mass spectroscopy (Takeda et al, 2001;Wolf et al, 2005), atomic absorption spectroscopy (Carpenter, 1981;Silva et al, 2004), X-ray fluorescence (Mihajlovic and Stafilov, 1998), electroanalytical methods (Ciszewski et al, 1997;Shams and Yekehtaz, 2002; ABSTRACT: Methylene blue has been proposed as a new analytical reagent for the catalytic spectrophotometric determination of thallium (I). It reacts with ascorbic acid in acidic medium to form a colorless product.…”
Section: Introductionmentioning
confidence: 99%