2004
DOI: 10.1016/j.nimb.2003.08.035
|View full text |Cite
|
Sign up to set email alerts
|

Determination of CR-39 detection efficiency for fast neutron registration and the absolute neutron dosimetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(5 citation statements)
references
References 8 publications
0
5
0
Order By: Relevance
“…ionization chamber, and the agreement between them is shown in Figure 2 (11)(12)(13). Figure 3(a) shows the good agreement between the monitor reading and TLD badge or card measurements in the presence of the slab phantom.…”
Section: Monitor (µSv/h) Chamber (µSv/h) Theoretical (µSv/h)mentioning
confidence: 71%
“…ionization chamber, and the agreement between them is shown in Figure 2 (11)(12)(13). Figure 3(a) shows the good agreement between the monitor reading and TLD badge or card measurements in the presence of the slab phantom.…”
Section: Monitor (µSv/h) Chamber (µSv/h) Theoretical (µSv/h)mentioning
confidence: 71%
“…With the information provided by the neutron spectra, the converter material could be selected looking for materials with high σ(n,x) charged particle. Several materials are employed as photoneutron converters depending upon the situation, whether the detector is used for dosimetry, spectrometry, or to measure the uranium concentration in tissues [62][63][64][65][66][67]. In table 7, we report some of them with relevant information.…”
Section: A Resume Of Photo-neutron Convertersmentioning
confidence: 99%
“…For the fast component of the neutron spectrum, El-Sersy et al [66] obtained an efficiency value of ε = 3.1 x 10 -5 tracks/neutron, probably employing cadmium filter as a cut-off for thermal neutrons.…”
Section: Determination Of Photo-neutron Fluence Ratementioning
confidence: 99%
“…However the cross-section, which is the geometric cross-section, for this collision is very low (1 barn) and only the proton recoil tracks close to the surface will be etched; those deeper in the bulk of CR-39 are not exposed to the etchant, and remain unobservable. So overall the sensitivity of CR-39 to neutrons is of the order of 10 −4 [11]. For the NX2 PF at optimum pressure and voltage, the neutron yield is of the order of 10 8 per shot.…”
Section: Charged Particles Recognitionmentioning
confidence: 99%