2007
DOI: 10.1016/j.polymertesting.2007.02.001
|View full text |Cite
|
Sign up to set email alerts
|

Determination of dn/dc values for ethylene–propylene copolymers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
23
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 33 publications
(25 citation statements)
references
References 13 publications
2
23
0
Order By: Relevance
“…Linear PE standards (Polymer Standard Service GmbH, Mainz, Germany), isotactic PP standards (American Polymer Standards, Mentor), linear PE with M w 260 kg/mol, iPP 200 kg/mol, and EP copolymers were dissolved in 1-decanol at a concentration of 1-2 mg/mL at 160 C. Samples of EP copolymers were prepared by Suarez 51,52 and described by Coto et al 53,54 The copolymerization reactions were carried out in a stirred tank reactor operating in semicontinuous mode at 70 C and 5 bar. Their molecular characterization data obtained with high-temperature SEC and NMR spectroscopy are summarized in Table I.…”
Section: Polymer Samplesmentioning
confidence: 99%
“…Linear PE standards (Polymer Standard Service GmbH, Mainz, Germany), isotactic PP standards (American Polymer Standards, Mentor), linear PE with M w 260 kg/mol, iPP 200 kg/mol, and EP copolymers were dissolved in 1-decanol at a concentration of 1-2 mg/mL at 160 C. Samples of EP copolymers were prepared by Suarez 51,52 and described by Coto et al 53,54 The copolymerization reactions were carried out in a stirred tank reactor operating in semicontinuous mode at 70 C and 5 bar. Their molecular characterization data obtained with high-temperature SEC and NMR spectroscopy are summarized in Table I.…”
Section: Polymer Samplesmentioning
confidence: 99%
“…The molecular weight and molecular weight distribution of the sample were measured using GPC/MALLS (Coto, Suárez, & Caballero, 2007;Liu, Bo, Zhang, & Zhu, 2003;Suárez, Caballero, & Coto, 2010). This process was performed on an infusion system (Waters 515 HPLC Unit Pump) fitted with one gel column (Shodex SB-806M) and the combined detectors (Wyatt-DAWN HELEOS ® eighteen-angle laser light scattering and Wyatt-Optilab rex refractive index detector).…”
Section: Molecular Weight Determinationmentioning
confidence: 99%
“…Temperature was also set at 145 • C. The DAWN EOS photometer system was calibrated with toluene, the detectors were normalized with a standard monodisperse PS (M w = 30 kg mol −1 ) which was also used to determine interdetector volume [20]. The differential refractive index increments dn/dc of the polymers and copolymers were determined following a procedure previously described [21]. Constant dn/dc values of 0.053 mL g −1 and 0.101 mL g −1 were used for PS and EP polymers, respectively.…”
Section: Gpc and Mals Characterizationmentioning
confidence: 99%
“…Constant dn/dc values of 0.053 mL g −1 and 0.101 mL g −1 were used for PS and EP polymers, respectively. dn/dc values for EP copolymers were considered composition independent according to previous work [21]. The software used was ASTRA V 5.1.9.1, from Wyatt Technology.…”
Section: Gpc and Mals Characterizationmentioning
confidence: 99%