1979
DOI: 10.1016/s0021-9673(00)92516-0
|View full text |Cite
|
Sign up to set email alerts
|

Determination of log Poct values of chloro-substituted benzenes, toluenes and anilines by high-performance liquid chromatography on ODS-silica

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
21
0

Year Published

1984
1984
2012
2012

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 120 publications
(22 citation statements)
references
References 16 publications
1
21
0
Order By: Relevance
“…9 In the perspective of a constructionist approach ,14,15 taking into account corrective factors for chain length, cycle effect, and steric hindrance to improve the fit between the predicted and experimental log P oct values, it became necessary to determine the log P oct of more lipophilic derivatives which are the most deviant. However, at this point we were faced with the problem that the conventional X Abstract published in Advance ACS Abstracts, August 1, 1996. shake-flask technique is not usable when log P oct is greater than 3.8-4.5 [16][17][18][19][20][21] according to the response of the solute to the analytical method used. It is well established that chromatography may provide quantitative information on the hydrophobicity of solute molecules.…”
Section: Introductionmentioning
confidence: 99%
“…9 In the perspective of a constructionist approach ,14,15 taking into account corrective factors for chain length, cycle effect, and steric hindrance to improve the fit between the predicted and experimental log P oct values, it became necessary to determine the log P oct of more lipophilic derivatives which are the most deviant. However, at this point we were faced with the problem that the conventional X Abstract published in Advance ACS Abstracts, August 1, 1996. shake-flask technique is not usable when log P oct is greater than 3.8-4.5 [16][17][18][19][20][21] according to the response of the solute to the analytical method used. It is well established that chromatography may provide quantitative information on the hydrophobicity of solute molecules.…”
Section: Introductionmentioning
confidence: 99%
“…Hydrophobicity determinations The apparent hydrophobicity of PDMS oligomers was measured by corrected retention times (i c = i r -I o ) in reversed-phase high performance liquid chromatography (RP-HPLC) on an octadecylsilica (C 18 ) column with methanol/water (90:10) as eluent. 11 ' 12 Apparent logP values were determined from retention indices using a homologous series of n-alkylbenzenes as reference compounds (see Ref. 13).…”
mentioning
confidence: 99%
“…1-Octanol and water are widely accepted as the best twophase system to model the partitioning between biomass and water. Despite the problems of emulsion formation associated with highly lipophilic substances [35] when the traditional shake-flask technique (SF) is used, this was the method of choice ahead of the stir-flask method (SS) [36] because the SS method would require long equilibration times of between 2 and 5 days.…”
Section: Octanol-water Partition Coefficientsmentioning
confidence: 99%