2009
DOI: 10.1016/j.talanta.2009.05.016
|View full text |Cite
|
Sign up to set email alerts
|

Determination of low level nitrite and nitrate in biological, food and environmental samples by gas chromatography–mass spectrometry and liquid chromatography with fluorescence detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
51
0
2

Year Published

2009
2009
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 107 publications
(53 citation statements)
references
References 42 publications
0
51
0
2
Order By: Relevance
“…Compared with the proposed method, a few other analytical methods show lower detection limits. 14,25 However, these methods are very expensive and highly sophisticated. In addition, in gas chromatography and spectrophotometric methods nitrite and nitrate must be derivitized in order to make them suitable for measurements.…”
Section: Calibration Curve and Analytical Parametersmentioning
confidence: 99%
See 1 more Smart Citation
“…Compared with the proposed method, a few other analytical methods show lower detection limits. 14,25 However, these methods are very expensive and highly sophisticated. In addition, in gas chromatography and spectrophotometric methods nitrite and nitrate must be derivitized in order to make them suitable for measurements.…”
Section: Calibration Curve and Analytical Parametersmentioning
confidence: 99%
“…Many methods, including spectrophotometric, 6,7 chromatographic, [8][9][10][11] potentiometric, 12,13 gas chromatographymass spectrometry (GC-MS) and liquid chromatography with fluorescence detection 14 and flow injection analysis [15][16][17] have been reported for the quantitative and qualitative analysis of nitrite and nitrate. Nonetheless, most of these methods suffer from a number of disadvantages, such as highly complication and laborious derivitization, the need for toxic reagents and harmful organic solvents, extensive sample preparation, time-consuming analysis, stability of the colored product formed, etc.…”
Section: Introductionmentioning
confidence: 99%
“…Chromatography detection systems include simple UV, fluorimetric, electron capture, electrochemical and mass spectroscopic [2,17,[31][32][33][34][35][36][37]. The popularity of UV detection lies in the simplicity of the approach and the ability to attenuate the detection wavelength.…”
Section: And Mohd Amri MD Yunus Techniques In Advancing the Capabilimentioning
confidence: 99%
“…A number of methods have been described in the literature for nitrite determination, which include spectrofluorometry, 7,8 chromatography, 9,10 electrochemical detection, 11,12 capillary electrophoresis, 13,14 flow injection analysis. 15, 16 Most of these methods are not suitable for routine determination of nitrite because some of them require expensive instruments or reagents, and others involve difficult and time-consuming separation procedures.…”
Section: Introductionmentioning
confidence: 99%