2011
DOI: 10.1039/c1an15423k
|View full text |Cite
|
Sign up to set email alerts
|

Determination of morphine at gold nanoparticles/Nafion® carbon paste modified sensor electrode

Abstract: A novel and effective electrochemical sensor for the determination of morphine (MO) in 0.04 mol L(-1) universal buffer solution (pH 7.4) is introduced using gold nanoparticles electrodeposited on a Nafion modified carbon paste electrode. The effect of various experimental parameters including pH, scan rate and accumulation time on the voltammetric response of MO was investigated. At the optimum conditions, the concentration of MO was determined using differential pulse voltammetry (DPV) in a linear range of 2.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
27
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 67 publications
(27 citation statements)
references
References 61 publications
(76 reference statements)
0
27
0
Order By: Relevance
“…Risperidone and olanzapine are both electroactive, but their quantification at bare electrodes, as for most of the organic molecules with similar structure, has a number of limitations, such as slow electron transfer reaction, electrode fouling problems [4] and, often, reduced linearity between concentration and current intensity [5].…”
Section: Introductionmentioning
confidence: 99%
“…Risperidone and olanzapine are both electroactive, but their quantification at bare electrodes, as for most of the organic molecules with similar structure, has a number of limitations, such as slow electron transfer reaction, electrode fouling problems [4] and, often, reduced linearity between concentration and current intensity [5].…”
Section: Introductionmentioning
confidence: 99%
“…While the analysis of pharmaceuticals has historically been carried out by spectrophotometry, fluorometry and liquid or gas chromatographic methods [ 2 ], recent investigations have focused on electrochemical methods [ 3 5 ], especially for neurological drug analytes [ 6 , 7 ]. Electrochemical methods enable several unique advantages [ 8 10 ].…”
Section: Introductionmentioning
confidence: 99%
“…Application of electrochemical methods proved to be highly sensitive and selective techniques [10][11][12] for the detection of biological materials [13,14]. Many complications face the use of the electrochemical methods such as the influence of many analytes interferences, which may be present at higher concentrations.…”
Section: Introductionmentioning
confidence: 99%