2016
DOI: 10.1134/s1061934816020052
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Rare earth elements in environmental samples by solid phase extraction ICP OES

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 14 publications
0
4
0
1
Order By: Relevance
“…In recent years, the method of solid phase extraction is used in sample preparation for analysis because of its high recovery, high enrichment factor, rapid phase separation, application of small volumes of organic solvents and low cost [2]. This method of samples pre-treatment is demanded even during the analysis of samples with such selective and highly sensitive methods as energy dispersive X-ray fluorescence and inductively coupled plasma [3][4][5][6][7][8]. The exclusion and regeneration of praseodymium from technological solution is also significant.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In recent years, the method of solid phase extraction is used in sample preparation for analysis because of its high recovery, high enrichment factor, rapid phase separation, application of small volumes of organic solvents and low cost [2]. This method of samples pre-treatment is demanded even during the analysis of samples with such selective and highly sensitive methods as energy dispersive X-ray fluorescence and inductively coupled plasma [3][4][5][6][7][8]. The exclusion and regeneration of praseodymium from technological solution is also significant.…”
Section: Introductionmentioning
confidence: 99%
“…Various sorbents are used for praseodymium preconcentration via solid phase extraction technique, such as modified silica gel [3,4], carbon-ferrite magnetic nanocomposite [5], Muromac A-1 resin [6], Chromosorb 106-TAR resin [7], and Fe 3 O 4 @TiO 2 @P 2 O 4 nanoparticles [8]. Xiong et al [9] studied the adsorption of Pr(III) from aqueous solutions using strongly acidic cation exchange resin D72.…”
Section: Introductionmentioning
confidence: 99%
“…Type of eluent and pH were optimized in our off-line previous work. 37 Sample flow rate, eluent flow rate, breakthrough volume and interfering elements were studied and optimized in this survey. The optimum instrumental conditions for ICP OES were done by experimental design based on Box-Behnken model.…”
Section: Resultsmentioning
confidence: 99%
“…35,36 Our research group has previously reported an off-line methodology with octadecyl silica gel modified with quinalizarin prior to ICP OES determination of REEs. 37 In the present work, a simple on-line procedure for pre-concentration and determination of trace levels REEs and uranium (U) in natural water samples and carbonate mineral by ICP OES is proposed. The mini column is packed with cotton roll dyed by quinalizarin as sorbent material.…”
Section: Introductionmentioning
confidence: 99%
“…Одним із шляхів розв'язання цих аналітичних та технологічних проблем є метод твердофазової екстракції з використанням різноманітних сорбентів [2][3][4]. Для концентрування лантаноїдів, зокрема Yb(III), використовували модифіковані силікагелі [5,6], багатостінні вуглецеві нанотрубки [7], магнітні наночастинки [8], сорбенти на основі графену [9,10], хелатні й іонообмінні смоли [11,12], а також синтетичні цеоліти [13,14].…”
Section: вступunclassified