2001
DOI: 10.1007/s002160100801
|View full text |Cite
|
Sign up to set email alerts
|

Determination of rare earth elements in environmental matrices by sector-field inductively coupled plasma mass spectrometry

Abstract: In the framework of an international certification campaign, sector-field inductively coupled plasma mass spectrometry (sector-field ICP-MS) was used for the accurate determination of the rare earth elements in five candidate reference materials: aquatic plant, calcareous soil, mussel tissue, river sediment, and tuna muscle. All samples were taken into solution by use of microwave-assisted or mixed microwave-assisted / open beaker acid digestion. Subsequently, the samples were appropriately diluted and subject… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
23
0

Year Published

2002
2002
2015
2015

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(23 citation statements)
references
References 0 publications
0
23
0
Order By: Relevance
“…Approximate values of REE contents are usually in the range of 150 mg kg -1 . Promethium, however, has been found only in very small amounts in uranium ore deposits [7].…”
Section: Introductionmentioning
confidence: 99%
“…Approximate values of REE contents are usually in the range of 150 mg kg -1 . Promethium, however, has been found only in very small amounts in uranium ore deposits [7].…”
Section: Introductionmentioning
confidence: 99%
“…The current analytical methods employed to analyze the lanthanides are generally: inter alia, 1,5 flame or graphite furnace atomic absorption spectrometry, [5][6][7] atomic absorption with chemical vapour generation, 5,[7][8] X-ray fluorescence spectrometry, 5,[7][8] inductively coupled plasma optical emission spectrometry, 5,[9][10][11] inductively coupled plasma mass spectrometry 5,10,12 and neutron activation analysis. 5,10,13 However, many of these methods require several time-consuming manipulation steps, sophisticated instruments and special training.…”
Section: Introductionmentioning
confidence: 99%
“…5,10,13 However, many of these methods require several time-consuming manipulation steps, sophisticated instruments and special training.…”
Section: Introductionmentioning
confidence: 99%
“…A significant problem in ICP-MS analysis of REEs of higher atomic numbers is spectral interferences of REEs of lower atomic numbers and/or barium oxide polyatomic species [12,[14][15][16][17][18][19]. In the case of instruments with lower resolution, separation procedures [12,16] or mathematical corrections are necessary [17][18][19]. TOF-ICP-MS (timeof-flight inductively coupled plasma mass spectrometry) is referred to be used to the determination of REEs with both types of TOF analyser -orthogonal [16] and axial [14].…”
Section: Introductionmentioning
confidence: 99%