2004
DOI: 10.1016/j.aca.2003.09.051
|View full text |Cite
|
Sign up to set email alerts
|

Determination of sulfur-containing amino acids by capillary electrophoresis dynamic reaction cell inductively coupled plasma mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
43
0

Year Published

2005
2005
2012
2012

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 50 publications
(43 citation statements)
references
References 32 publications
0
43
0
Order By: Relevance
“…Although the system proved to be robust, requiring minute sample volumes (only about 20 nL are injected into the capillary) and providing reproducible results with short analysis times (less than 10 min), implementation of reaction/collision cell technology for more accurate determination of the protein content would be favorable [46,47]. Complimentary CE-ESI-MS experiments would also help in the elucidation of the exact structure of the adducts, whereas application of capillary IEF for better separation of the proteins would surely aid in the identification of the drug's less abundant binding partners.…”
Section: Discussionmentioning
confidence: 99%
“…Although the system proved to be robust, requiring minute sample volumes (only about 20 nL are injected into the capillary) and providing reproducible results with short analysis times (less than 10 min), implementation of reaction/collision cell technology for more accurate determination of the protein content would be favorable [46,47]. Complimentary CE-ESI-MS experiments would also help in the elucidation of the exact structure of the adducts, whereas application of capillary IEF for better separation of the proteins would surely aid in the identification of the drug's less abundant binding partners.…”
Section: Discussionmentioning
confidence: 99%
“…Iodine disinfection by-products, in particular iodphenols, were determined in river water by Kannamkumarath et al [194]. Their method involves offline SPME followed by analysis of the extracts using CE coupled to ICP-MS. Sulfur containing amino acids were investigated employing CE-ICP-MS with a dynamic reaction cell by Yeh et al [195]. Analytes included in this study were cysteine, cystine, homocystine, and methionine, which were determined in urine and nutritive complement samples.…”
Section: Applications Of Ce-icp-msmentioning
confidence: 99%
“…A detailed description of the CEI-100 CE interface (CETAC, Omaha, NE, USA) was given in previous papers [17,21]. The nebulizer worked in the self-aspiration mode at a flow rate of around 5.5 mL/min [22]. A 0.1% v/v HNO 3 solution containing 5% methanol was used as the make-up solution to provide the electrical connection and to reduce surface …”
Section: Ce-icp-ms Systemmentioning
confidence: 99%