2016
DOI: 10.1016/j.nimb.2016.01.011
|View full text |Cite
|
Sign up to set email alerts
|

Determination of the detection threshold for Polyethylene Terephthalate (PET) Nuclear Track Detector (NTD)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2017
2017
2019
2019

Publication Types

Select...
5
1
1

Relationship

3
4

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 16 publications
0
7
0
Order By: Relevance
“…Poly(ethylene terephthalate), PET, has been recognized as an etched track detector with relatively high detection thresholds depending on the industrial products (Bhattacharyya et al, 2016;Drach et al, 1987;Somogyi et al, 1976). Stacked PET detectors with different kinds of detectors of poly(allyl diglycol carbonate), PADC, and polyimide (Kapton) have made it possible to identify the nuclear charge of heavy ions from the intense laser plasma in complex radiation fields (Nishiuchi et al, 2015).…”
Section: Introductionmentioning
confidence: 99%
“…Poly(ethylene terephthalate), PET, has been recognized as an etched track detector with relatively high detection thresholds depending on the industrial products (Bhattacharyya et al, 2016;Drach et al, 1987;Somogyi et al, 1976). Stacked PET detectors with different kinds of detectors of poly(allyl diglycol carbonate), PADC, and polyimide (Kapton) have made it possible to identify the nuclear charge of heavy ions from the intense laser plasma in complex radiation fields (Nishiuchi et al, 2015).…”
Section: Introductionmentioning
confidence: 99%
“…129 Xe, 78 Kr, 49 Ti beams at REX-ISOLDE CERN [17]; 56 Fe, 32 S, 16 O beams at IUAC [24]; 12 C beam at IOP [25]. In Fig.…”
Section: Calibration Of Pet Nuclear Track Detectormentioning
confidence: 96%
“…In previous calibration campaigns, PET films had been irradiated with 238 U, 129 Xe, 78 Kr, 49 Ti beams at REX-ISOLDE CERN [17]; 56 Fe, 32 S, 16 O beams at IUAC [24]; 12 C beam at IOP [25]. In Fig.…”
Section: Calibration Of Pet Nuclear Track Detectormentioning
confidence: 99%
“…Detection threshold of PET is very high; it detected fission fragments but did not detect alpha particles when exposed to Cf 252 source [1]. We have optimised the etching conditions and characterization and calibration have been done for this detector using several different ions from accelerators in India and abroad [2][3][4][5]. Now PET is a well established passive detector.…”
Section: Introductionmentioning
confidence: 99%