2014
DOI: 10.1039/c4ra10218e
|View full text |Cite
|
Sign up to set email alerts
|

Determination of trace analytes based on diffuse reflectance spectroscopic techniques: development of a multichannel membrane filtration-enrichment device to improve repeatability

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 31 publications
0
9
0
Order By: Relevance
“…The membrane ltration-enrichment process was carried out by the homemade six-channel membrane ltration-enrichment device utilized in our previous study. 21 A laboratory-made digital image acquirement system (Fig. 2) consisted of a foam box of approximately 31 cm  24 cm  17 cm, which was equipped with two LED lamps with 84 guide plates (14.5 cm  6 cm, 20 W) to provide a uniform illumination.…”
Section: Apparatusmentioning
confidence: 99%
See 2 more Smart Citations
“…The membrane ltration-enrichment process was carried out by the homemade six-channel membrane ltration-enrichment device utilized in our previous study. 21 A laboratory-made digital image acquirement system (Fig. 2) consisted of a foam box of approximately 31 cm  24 cm  17 cm, which was equipped with two LED lamps with 84 guide plates (14.5 cm  6 cm, 20 W) to provide a uniform illumination.…”
Section: Apparatusmentioning
confidence: 99%
“…It is necessary to investigate and optimize them to obtain the highest possible sensitivity. In our previous research, 21 these parameters have been thoroughly optimized and reported in detail. The optimal experiments in this study were investigated by both digital image colorimetry and UV-vis spectral analysis, and the obtained results are very similar.…”
Section: Optimization Of Experimental Conditionsmentioning
confidence: 99%
See 1 more Smart Citation
“…The membrane ltration-enrichment process was carried out by the homemade six-channel membrane ltration-enrichment device utilized in our previous study. 13 The selected membrane lters were stacked up and placed between the multichannel solution importer and the ltration device (Fig. 1).…”
Section: Apparatusmentioning
confidence: 99%
“…[1][2][3] It has received considerable attention and has been widely used for the separation and preconcentration of trace metallic ions aer chromogenic reactions [4][5][6][7][8][9][10] and for several organic compounds. [11][12][13][14][15][16][17][18] Unlike most of the studies, our group 4,9,11,12 simplied the detection process by omitting the elution step and directly measuring the diffuse reectance spectrum of the membrane lter concentrated analytes, i.e. on-line spectroscopic determination.…”
Section: Introductionmentioning
confidence: 99%