2009
DOI: 10.1016/j.aca.2009.05.022
|View full text |Cite
|
Sign up to set email alerts
|

Determination of trace elements in biological samples by inductively coupled plasma mass spectrometry with tetramethylammonium hydroxide solubilization at room temperature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
45
0
5

Year Published

2009
2009
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 94 publications
(50 citation statements)
references
References 30 publications
0
45
0
5
Order By: Relevance
“…17,19,20,21,22,23 These interferences can be minimized or even removed by using a reaction and/or collision cell. 14,17,18,24,25 Page 3 of 39 Journal of Analytical Atomic Spectrometry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 4 Non-spectral interferences can also be found when carrying out the analysis of blood samples. Therefore, high concentrations of inorganic and organic solutes may cause changes in the aerosol generation, transport and/or the properties of the plasma.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…17,19,20,21,22,23 These interferences can be minimized or even removed by using a reaction and/or collision cell. 14,17,18,24,25 Page 3 of 39 Journal of Analytical Atomic Spectrometry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 4 Non-spectral interferences can also be found when carrying out the analysis of blood samples. Therefore, high concentrations of inorganic and organic solutes may cause changes in the aerosol generation, transport and/or the properties of the plasma.…”
mentioning
confidence: 99%
“…Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES), 5,11,12 and, particularly, Mass Spectrometry (ICP-MS) 5,13,14,15,16,17 offer multi-elemental measurement capability, low detection limits, 18 wide dynamic range and short analysis time. 16 However, these techniques suffer from spectral as well as non-spectral interferences that may degrade the accuracy of blood analysis.…”
mentioning
confidence: 99%
“…The sample introduction system was composed of a quartz cyclonic spray chamber and a Meinhard ® nebulizer connected by Tygon ® tubes to the peristaltic pump of the ICP-MS. The instrument settings and other operating conditions for analysis were according to Batista and colleagues [17].…”
Section: Chemicals and Instrumentsmentioning
confidence: 99%
“…1,6 The analysis of trace elements in biological samples is predominantly performed using atomic spectrometry techniques, such as atomic absorption spectrometry (AAS), [15][16][17][18][19][20][21][22][23] inductively coupled plasma emission spectrometry (ICP-OES) 24 and inductively coupled plasma mass spectrometry (ICP-MS). [25][26][27][28][29] ICP-MS offers several advantages, including simultaneous multielement measurement capability coupled with very low limits of detection, a wider linear dynamic range, allowing the determination of major and trace elements at the same sample injection and isotopic information.…”
Section: Introductionmentioning
confidence: 99%