2018
DOI: 10.5194/amt-11-4361-2018
|View full text |Cite
|
Sign up to set email alerts
|

Determining the link between hygroscopicity and composition for semi-volatile aerosol species

Abstract: Abstract. Internally and externally mixed aerosols present significant challenges in assessing the hygroscopicity of each aerosol component. This study presents a new sampling technique which uses differences in volatility to separate mixtures and directly examine their respective composition and hygroscopic contribution. A shared thermodenuder and unheated bypass line are continuously cycled between an aerosol mass spectrometer and a volatility and hygroscopicity tandem differential mobility analyser, allowin… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
9
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(10 citation statements)
references
References 55 publications
1
9
0
Order By: Relevance
“…Size distributions and number concentrations of 10 to 300 nm diameter SSA were measured using a TSI 3080 scanning mobility particle sizer (SMPS), coupled with a 3071 differential mobility analyser and a 3010 condensation particle counter (CPC) (TSI, Shoreview, MN), with an aerosol sample flow rate of 1 L min −1 and a sheath flow rate of 10 L min −1 . The volatility and hygroscopicity of nascent SSA was determined with a volatility and hygroscopicity tandem differential mobility analyser (VH-TDMA) (Alroe et al, 2018;Johnson et al, 2008Johnson et al, , 2004. The VH-TDMA selects particles based on mobility diameter, conditions them, and measures the resulting particle size distributions using parallel SMPSs (V-SMPS and H-SMPS in Fig.…”
Section: Measurements/instrumentationmentioning
confidence: 99%
See 3 more Smart Citations
“…Size distributions and number concentrations of 10 to 300 nm diameter SSA were measured using a TSI 3080 scanning mobility particle sizer (SMPS), coupled with a 3071 differential mobility analyser and a 3010 condensation particle counter (CPC) (TSI, Shoreview, MN), with an aerosol sample flow rate of 1 L min −1 and a sheath flow rate of 10 L min −1 . The volatility and hygroscopicity of nascent SSA was determined with a volatility and hygroscopicity tandem differential mobility analyser (VH-TDMA) (Alroe et al, 2018;Johnson et al, 2008Johnson et al, , 2004. The VH-TDMA selects particles based on mobility diameter, conditions them, and measures the resulting particle size distributions using parallel SMPSs (V-SMPS and H-SMPS in Fig.…”
Section: Measurements/instrumentationmentioning
confidence: 99%
“…Externally mixed organics have also been observed to comprise the majority of the number concentration of sub-180 nm SSA in some studies (Collins et al, 2014(Collins et al, , 2013Prather et al, 2013). It should be noted that the externally mixed organic fraction still contained inorganic ions but was characterised by an absence of Cl (Ault et al, 2013a).…”
Section: Introductionmentioning
confidence: 96%
See 2 more Smart Citations
“…Size distributions and number concentrations of 10 to 300 nm diameter SSA were measured using a TSI 3080 scanning mobility particle sizer (SMPS), coupled with a 3071 differential mobility analyser and a 3010 condensation particle counter (CPC) (TSI, Shoreview, MN), with an aerosol sample flow rate of 1 L min −1 and a sheath flow rate of 10 L min −1 . The volatility and hygroscopicity of nascent SSA was determined with a volatility and hygroscopicity tandem differential mobility analyser (VH-TDMA) (Alroe et al, 2018;Johnson et al, 2008Johnson et al, , 2004. The VH-TDMA selects particles based on mobility diameter, conditions them, and measures the resulting particle size distributions using parallel SMPSs (V-SMPS and H-SMPS in Fig.…”
Section: Measurements/instrumentationmentioning
confidence: 99%