Abstract:The paper considers methods for calculating the rate of metals corrosion. A comparative analysis of the experimental data on the steel 10 corrosion rate in carbonate solutions with different pH values (6-12.5) and the concentration of carbonate ions on the disk electrode made of steel 10. The calculation of the corrosion rate by the gravimetric method and the method of polarization resistance is carried out. A detailed description of the calculating the corrosion rate stages index from experimental electrochem… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.