Developed model and simulation of primary and secondary arc fault on transmission lines using MATLAB

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 3 publications
0
2
0
Order By: Relevance
“…Significant opportunities for compensation of the secondary arc have emerged due to static thyristor compensators (STC) with phaseindependent control. It is possible to select the equivalent parameters of the STC in such a way as to completely compensate for the corresponding system of partial line capacitances and thereby reduce the secondary arc currents to almost zero using automatic changes of the control angles of the thermistor switches [14][15][16][17][18][19][20]. In this case, the control angles of the thermistor switches of the STC will depend only on the disconnected phase of the line.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Significant opportunities for compensation of the secondary arc have emerged due to static thyristor compensators (STC) with phaseindependent control. It is possible to select the equivalent parameters of the STC in such a way as to completely compensate for the corresponding system of partial line capacitances and thereby reduce the secondary arc currents to almost zero using automatic changes of the control angles of the thermistor switches [14][15][16][17][18][19][20]. In this case, the control angles of the thermistor switches of the STC will depend only on the disconnected phase of the line.…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, the effectiveness of methods used for reducing secondary arc currents and recovering depends on the location of the arc and its extinction. Implementation of the SPAR in AC power transmission is hampered by the presence of a place recharge short circuit on the side of non-disconnected phases [19][20][21][22][23][24]. Mode parameters determining the conditions for extinguishing the secondary arc are as follows: secondary current of the arc flowing in the arc before it is extinguished, I d ; recovery stress in the place of short circuit after the extinction of the secondary arc current.…”
Section: Introductionmentioning
confidence: 99%