2007
DOI: 10.1016/j.jcms.2006.11.006
|View full text |Cite
|
Sign up to set email alerts
|

Development and biomechanical testing of a new osteosynthesis plate (TCP®) designed to stabilize mandibular condyle fractures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
40
0
3

Year Published

2008
2008
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 78 publications
(44 citation statements)
references
References 41 publications
1
40
0
3
Order By: Relevance
“…A single L, Y plate, or 3-D plate has been used in the treatment of condylar fractures, 16 which confirm to the tensile stress pattern at the condylar neck region. Trapezoidal condylar plate (TCP) is such a 3-D plate shaped for adaptation in the anatomically constricted region of condylar neck.…”
Section: Introductionmentioning
confidence: 71%
See 1 more Smart Citation
“…A single L, Y plate, or 3-D plate has been used in the treatment of condylar fractures, 16 which confirm to the tensile stress pattern at the condylar neck region. Trapezoidal condylar plate (TCP) is such a 3-D plate shaped for adaptation in the anatomically constricted region of condylar neck.…”
Section: Introductionmentioning
confidence: 71%
“…Hence, this plate meets the criteria of 2 single miniplates with reduced hardware, leading to a less infection rate. 16 The aim of this study was to evaluate the efficacy of single trapezoidal 3-D miniplates in subcondylar fractures.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, their smaller size helps to avoid excessive soft tissue stripping during surgery and improves handling in minimally invasive surgical approaches. Actual clinical results have suggested that use of these 3D plates is superior to the previous two miniplates technique 4,7) . Furthermore, visual analyses of the macroscopic fracture line displacement and photoelastimetric analysis of the pre-and postsurgical strain patterns have been reported 4,6,7) .…”
Section: Discussionmentioning
confidence: 91%
“…Actual clinical results have suggested that use of these 3D plates is superior to the previous two miniplates technique 4,7) . Furthermore, visual analyses of the macroscopic fracture line displacement and photoelastimetric analysis of the pre-and postsurgical strain patterns have been reported 4,6,7) . According to Champy et al 8) , as a rule, internal rigid fixation has to be sufficiently stable in mandibular fracture ORIF to fulfill the principles of functionally stable osteosynthesis and thus induce sound bone healing.…”
Section: Discussionmentioning
confidence: 91%
See 1 more Smart Citation