2017
DOI: 10.1111/ics.12393
|View full text |Cite
|
Sign up to set email alerts
|

Development and clinical validation of a novel photography‐based skin erythema evaluation system: a comparison with the calculated consensus of dermatologists

Abstract: A new erythema evaluation system was developed and validated through CCAE, suggesting that the system can support dermatologists' objective diagnoses of erythema.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 41 publications
0
4
0
Order By: Relevance
“…Furthermore, taking the CADESI-04based scale as a reference, the erythema detection accuracy reached 89.5%, which is comparable to a similar study in humans (93.2%). 9 When the overall classification accuracy was studied, our system (71.1%) exceeded that of a system with a digital camera in humans with psoriasis (48.8%); 7 however, the erythema severity scale in the Psoriasis Area and Severity Index (PASI) included one additional erythema grading category (i.e. 5).…”
Section: Discussionmentioning
confidence: 83%
See 1 more Smart Citation
“…Furthermore, taking the CADESI-04based scale as a reference, the erythema detection accuracy reached 89.5%, which is comparable to a similar study in humans (93.2%). 9 When the overall classification accuracy was studied, our system (71.1%) exceeded that of a system with a digital camera in humans with psoriasis (48.8%); 7 however, the erythema severity scale in the Psoriasis Area and Severity Index (PASI) included one additional erythema grading category (i.e. 5).…”
Section: Discussionmentioning
confidence: 83%
“…In humans, various imaging devices [7][8][9] objectively estimate the erythema severity by calculating the ratio between spectral bands, the so-called erythema index (EI). In veterinary medicine, to the best of our knowledge, there has been only one attempt to use cameras or spectrometers for estimating canine erythema, where the acquired data were converted to the standard CIELAB colour space, which corresponds to the spectrum of normal human vision.…”
Section: Introductionmentioning
confidence: 99%
“…In our colonoscopy video, a 0.5 s period yielded optimal results. As the standard setting, observing the colonoscopy video at a speed of 0.7 times to avoid misreading directions, participation of five fellow doctors, and selecting values more than three made the accuracy of the gold standard more reliable (Cho et al, 2016; Fallah & Niakan Kalhori, 2017; Cho et al, 2017)…”
Section: Discussionmentioning
confidence: 99%
“…Currently, specialists sample skin images manually by selecting specific pixels or small areas [17,19,21]. On the other hand, there are a few semi-automated approaches [6,28], where the user would select erythematous and native skin areas with the representative erythematous skin being determined by the redness gradient-or fuzzy entropy-based algorithm.…”
Section: Introductionmentioning
confidence: 99%