2002
DOI: 10.1016/s0021-8502(02)00055-1
|View full text |Cite
|
Sign up to set email alerts
|

Development and evaluation of a personal cascade impactor sampler (PCIS)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
146
0
2

Year Published

2003
2003
2020
2020

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 194 publications
(148 citation statements)
references
References 21 publications
0
146
0
2
Order By: Relevance
“…Particles are separated in the aerodynamic particle diameter of quasi-ultrafine mode (Dp < 0.25 µm; PM 0.25 ), accumulation mode (0.25-0.5 µm, 0.5-1.0 µm, 1.0-2.5 µm; PM 0.25-2.5 ) and coarse (2.5-10 µm; PM 2.5-10 ). 42,43 The impactors were placed 1.5 m above ground level and particulate matter was collected with Teflon filters (25 and 37 mm diameter). After being weighed, the membranes were immediately frozen and kept in a refrigerator until analysis.…”
Section: Sampling Methodsmentioning
confidence: 99%
“…Particles are separated in the aerodynamic particle diameter of quasi-ultrafine mode (Dp < 0.25 µm; PM 0.25 ), accumulation mode (0.25-0.5 µm, 0.5-1.0 µm, 1.0-2.5 µm; PM 0.25-2.5 ) and coarse (2.5-10 µm; PM 2.5-10 ). 42,43 The impactors were placed 1.5 m above ground level and particulate matter was collected with Teflon filters (25 and 37 mm diameter). After being weighed, the membranes were immediately frozen and kept in a refrigerator until analysis.…”
Section: Sampling Methodsmentioning
confidence: 99%
“…It Figure S1 and its further description can be found elsewhere (Misra et al, 2002;Sioutas, 2004). To ensure that the particles are separated precisely in these size-bins, the PCIS must be used with a Leland Legacy Sample Pump (SKC Inc., Cat.…”
Section: Instrumentationmentioning
confidence: 99%
“…Teflon is preferred for collecting such particles since this does not interfere with gravimetric analysis and chemical composition (Misra et al, 2002).…”
Section: Instrumentationmentioning
confidence: 99%
“…The site is in-between two subway stations and one block north of the main thoroughfare through the neighborhood. One Sioutas personal cascade impactor sampler (PCIS) (Misra et al 2002;Singh et al 2003) was employed operating at 9 Lpm for 24 hours. This sampler separates the PM into five size-fractions (>2.5 µm, 2.5-1 µm, 1-0.5 µm, 0.5-0.25 µm, and <0.25 µm) allowing for size-fractionated chemical-speciation data.…”
Section: Particulate Matter Samplingmentioning
confidence: 99%