2009
DOI: 10.1080/00365510902981171
|View full text |Cite
|
Sign up to set email alerts
|

Development and performance of an enzyme immunoassay to detect creatine kinase isoenzyme MB activity using anti-mitochondrial creatine kinase monoclonal antibodies

Abstract: Our method is novel in offering higher accuracy of measuring true CK-MB contents in human serum as compared to the conventional method. The possibility of accurately estimating CK-MB activity by our method which can inhibit MtCKs in healthy person and patient serum is likely to bring a break-through in clinical diagnostics.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…We measured the serum MtCK activity according to a previously reported method [23]. Conventional assay of CK-MB activity is an immunoinhibition method against the MM fraction of creatine kinase (CK-M).…”
Section: Methodsmentioning
confidence: 99%
“…We measured the serum MtCK activity according to a previously reported method [23]. Conventional assay of CK-MB activity is an immunoinhibition method against the MM fraction of creatine kinase (CK-M).…”
Section: Methodsmentioning
confidence: 99%
“…The L-System CK-MB MtO (Sysmex Corporation, Kobe, Japan), a new reagent kit that can be used to measure CK-MB activity and inhibit MtCK activity, was developed recently [9,10]. Here, we evaluated the clinical usefulness of this new CK-MB reagent, which includes anti-MtCK antibodies and abrogates the effect of MtCK activity in the serum, and confirmed the clinical efficacy of inhibition of MtCK activity.…”
Section: Introductionmentioning
confidence: 56%
“…The intercept of the linear regression equation was approximately 9 U/L and appeared to correspond to MtCK activity in patient sera. MtCK activity is present in the serum of healthy individuals, and it was 3.8 U/L in an immunoinhibition assay [10]. MtCK activity in serum was calculated by subtracting CK-B activity determined using the new method from that determined using the conventional kit.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…MtCK activity was measured with an immune‐inhibition method using two types of anti‐MtCK monoclonal antibodies, that is, an anti‐uMtCK monoclonal antibody and an anti‐sMtCK monoclonal antibody in addition to an anticreatine kinase‐M antibody as described previously . JCA‐BM8040 (JEOL, Tokyo, Japan) was used as an automatic analyzer.…”
Section: Methodsmentioning
confidence: 99%