2020
DOI: 10.1016/j.jchromb.2020.122299
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of a UPLC-MS/MS method to quantify fructose in serum and urine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 25 publications
0
5
0
Order By: Relevance
“…Twenty-four-hour urinary fructose levels, used as a biomarker of dietary fructose intake and, hence, adherence [24], showed a very similar pattern (Supplementary Figure 2D). Serum uric acid levels, but not 24 h urinary uric acid levels, showed a borderline significant reduction in the intervention group only (Supplementary Figure 3A-B).…”
Section: Randomization and Follow Upmentioning
confidence: 77%
See 2 more Smart Citations
“…Twenty-four-hour urinary fructose levels, used as a biomarker of dietary fructose intake and, hence, adherence [24], showed a very similar pattern (Supplementary Figure 2D). Serum uric acid levels, but not 24 h urinary uric acid levels, showed a borderline significant reduction in the intervention group only (Supplementary Figure 3A-B).…”
Section: Randomization and Follow Upmentioning
confidence: 77%
“…Insulin resistance was estimated with the homeostasis model assessment of insulin resistance (HOMA2-IR) calculator (www.dtu.ox.ac.uk). A 24-hour urine sample was collected at baseline and at completion in pre-acidified plastic containers for determination of sodium (Indirect ISE-method, Cobas 8000 instrument, Roche Diagnostics, Mannheim, Germany), fructose (Ultra Performance Liquid Chromatography-tandem Mass Spectrometry [24], and uric acid levels (Enzymatic colorimetric assay, Cobas 8000 instrument, Roche Diagnostics, Mannheim, Germany).…”
Section: Other Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…Plasma glucose levels were determined every 15 min by using the YSI2300 STAT Plus Glucose Lactate Analyser (YSI, Yellow Springs, OH). Serum fructose concentrations were measured with a recently developed and validated Ultra Performance Liquid Chromatography–tandem Mass Spectrometry method [ 15 ]. Serum lipids were measured by an enzymatic colorimetric assay (Cobas 8000 instrument, Roche Diagnostics, Mannheim, Germany).…”
Section: Methodsmentioning
confidence: 99%
“…Compared to NMR, MS has a much higher sensitivity and is therefore able to measure a wider range of metabolites ( 40 , 43 , 73 , 74 ). In particular, UPLC offers excellent chromatographic separation, high speed, and high sensitivity, allowing the detection of thousands of metabolites within a short time ( 75 78 ). HPLC tandem MS plays a huge contribution in research that requires high throughput, such as natural drug development and disease biomarker identification ( 79 83 ).…”
Section: Metabolomics Analysis Platformmentioning
confidence: 99%