Development and Validation of a New Generation of Flexible Endoscope for NOTES

Abstract: A new flexible access endoscope with 4 large access channels showed utility in a cadaver model-satisfying some of the requirements for performance of NOTES procedures.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
25
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 28 publications
(25 citation statements)
references
References 8 publications
0
25
0
Order By: Relevance
“…16,33 Current research on developing instruments to aid performing pure NOTES is underway. 34,35 For further incorporation into humans, fundamental steps and elements present in all procedures, as well as practical and technical challenges, will need to be resolved.…”
Section: Minimalmentioning
confidence: 99%
“…16,33 Current research on developing instruments to aid performing pure NOTES is underway. 34,35 For further incorporation into humans, fundamental steps and elements present in all procedures, as well as practical and technical challenges, will need to be resolved.…”
Section: Minimalmentioning
confidence: 99%
“…This study aimed to evaluate the feasibility of a minimally invasive transtracheal endoscopic technique for thoracic cavity evaluation in canine models (Figs. 1,2,3,4).Two dogs were used as our study objects. For both procedures, anesthesia of canine models was induced using tiletamine hydrochloride and zolazepam hydrochloride (0.1 ml/kg Zoletil 50, Virbac, Carros; France) and xylazine hydrochloride (0.1 ml/kg Rompon, Bayer, Leverkusen; Germany) followed by maintenance with endotracheally administered isofulrance (2.5%).…”
mentioning
confidence: 99%
“…Further investigations should include refinement of incision site closure, improvement of surgical instruments (small-caliber fiberoptic scope), and more reliance on incision wound sealants [1][2][3][4].…”
mentioning
confidence: 99%
“…Triangulation allows the surgeon to accomplish traction and counter traction of tissue, fine dissection, and suturing and is one of the most essential concepts in laparoscopy [Wang and Meng, 2012]. Triangulation is also essential in natural orifice surgery with flexible tools [Swanstrom, 2009;Rattner and Kalloo, 2006;von Renteln, 2011]. Currently, gastroenterologists manipulate the endoscope tip including the camera and the instrument, that protrudes from the tip, to perform therapy.…”
Section: Design Directions For Robotic Instrument Manipulationmentioning
confidence: 99%
“…[Swanstrom 2009;Thompson et al, 2009] Boston Scientific Corporation, Natick, MA, USA Nanyang University endoscopic system Cobra [Wang and Meng, 2012] [ Wang and Meng, 2012] The robotic slave of the Nanyang University (see also Section 1.5) is a cable driven end effector of round 22 mm that can be mounted on existing endoscopes. The six-DOF instruments are modeled after a simplified human arm.…”
Section: Anubis Notescopementioning