2007
DOI: 10.1016/j.jchromb.2007.02.025
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of a liquid chromatography—tandem mass spectrometric method for the determination of the major metabolites of duloxetine in human plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
17
0

Year Published

2007
2007
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(17 citation statements)
references
References 10 publications
0
17
0
Order By: Relevance
“…It is noted that the fitted charge transfer resistance (R ct ) value of the MWCNT/GCE is much lower than that of the bare GCE, suggesting that the MWCNT has high conductivity. For the MWCNT@GONR/GCE, the R ct increases obviously, this indicates that the electron transfer of the electrochemical probe Fe(CN) 6 3-/4-on the MWCNT@GONR/GCE is obstructed by GONR due to the poor electronic conductivity of GONR. However, the R ct for MWCNT@rGONR/GCE i s d r a m a t i c a l l y d e c r e a s e d , i m p l y i n g t h a t t h e MWCNT@rGONR has excellent conductivity after the reduction of MWCNT@GONR.…”
Section: Characterization Of Mwcnt@rgonrmentioning
confidence: 98%
See 2 more Smart Citations
“…It is noted that the fitted charge transfer resistance (R ct ) value of the MWCNT/GCE is much lower than that of the bare GCE, suggesting that the MWCNT has high conductivity. For the MWCNT@GONR/GCE, the R ct increases obviously, this indicates that the electron transfer of the electrochemical probe Fe(CN) 6 3-/4-on the MWCNT@GONR/GCE is obstructed by GONR due to the poor electronic conductivity of GONR. However, the R ct for MWCNT@rGONR/GCE i s d r a m a t i c a l l y d e c r e a s e d , i m p l y i n g t h a t t h e MWCNT@rGONR has excellent conductivity after the reduction of MWCNT@GONR.…”
Section: Characterization Of Mwcnt@rgonrmentioning
confidence: 98%
“…Figure 3 shows the electrochemical impedance analysis (EIS) results of different electrodes recorded in 5 mM Fe(CN) 6 3-/4-and 0.1 M KCl aqueous solution. It is noted that the fitted charge transfer resistance (R ct ) value of the MWCNT/GCE is much lower than that of the bare GCE, suggesting that the MWCNT has high conductivity.…”
Section: Characterization Of Mwcnt@rgonrmentioning
confidence: 99%
See 1 more Smart Citation
“…By literature survey, several analytical techniques have been stated for DLX determination in its pure form, pharmaceuticals and bio-fluids, where DLX is not specifically assigned to any pharmaceutical constitution. These techniques include highperformance liquid chromatography, [2,3] liquid chromatography joined with mass spectrometry, [4][5][6] high-performance thinlayer chromatography, [7] spectrofluorimetry, [8] spectrophotometry, [9] and capillary zone electrophoresis. [10] Although these techniques are very sensitive, and not adapted for in situ, and DLX real-time detection also takes a long time, involve expensive devices and skilled technicians are required.…”
Section: Introductionmentioning
confidence: 99%
“…After oral administration, the drug is well absorbed, protein binding is relevant (96%) and the mean elimination half-life is 12 h [5]. DLX is metabolised in the liver by the cytocrome P450 system (in particular the CYP1A2 and CYP2D6 isoforms) to inactive metabolites (4-hydroxy duloxetine glucuronide and 5-hydroxy-6-methoxy duloxetine sulphate are the most abundant), which are excreted in the urine [7,8].…”
Section: Introductionmentioning
confidence: 99%