2013
DOI: 10.1016/j.domaniend.2013.05.003
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of a sensitive enzyme immunoassay (EIA) for blood plasma cortisol in female cattle, buffaloes, and goats

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
8
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 18 publications
1
8
0
Order By: Relevance
“…Because HA concentrations between 1 and 20nM could be arduous to interpret for clinicians [20], a focus was made on samples displaying concentrations measured by RIA comprised in this range (n=47), and a Pearson's correlation coefficient of 0.88 (95% CI 0.80-0.93; p<0.0001) was calculated ( Figure 1C). The subsequent Bland-Altman plot showed an estimated bias of +2.97nM (SD: 3.08nM; 95% limits of agreement: -3.07 -9.01nM) ( In conclusion, besides a slight overestimation of HA concentrations, all these observations support the hypothesis that EIA can be a favorable alternative to RIA, as described previously for other molecules like progesterone, cortisol, or infliximab [21][22][23].…”
Section: High Resolution Accurate Mass Lc-ms Technologysupporting
confidence: 83%
“…Because HA concentrations between 1 and 20nM could be arduous to interpret for clinicians [20], a focus was made on samples displaying concentrations measured by RIA comprised in this range (n=47), and a Pearson's correlation coefficient of 0.88 (95% CI 0.80-0.93; p<0.0001) was calculated ( Figure 1C). The subsequent Bland-Altman plot showed an estimated bias of +2.97nM (SD: 3.08nM; 95% limits of agreement: -3.07 -9.01nM) ( In conclusion, besides a slight overestimation of HA concentrations, all these observations support the hypothesis that EIA can be a favorable alternative to RIA, as described previously for other molecules like progesterone, cortisol, or infliximab [21][22][23].…”
Section: High Resolution Accurate Mass Lc-ms Technologysupporting
confidence: 83%
“…The validation techniques used in this study for FGM analysis have been previously used in other studies (Bashaw et al, 2016;Chinnadurai et al, 2009;Morrow, Kolver, Verkerk, & Matthews, 2002;Yadav et al, 2013), but obtaining a biological validation (i.e., an ACTH challenge) for this study was not possible. We validated the assay biochemically for this species and monitored variability between assays using quality high and low controls.…”
Section: Fecal Hormone Extraction and Assay Analysesmentioning
confidence: 99%
“…Many analytical methods have been proposed for the detection of steroid hormones in biological specimens. Although immunoassays have routinely been used to measure steroid hormones in clinical applications because of the method's simplicity and sensitivity, limitations of the method including poor specificity and the limited dynamic range. Due to the low volatilities of hormones, the general application of gas chromatography/mass spectrometry (GC/MS)‐based analysis was hampered by the time‐consuming derivatization step .…”
Section: Introductionmentioning
confidence: 99%