2022
DOI: 10.7759/cureus.24548
|View full text |Cite
|
Sign up to set email alerts
|

Development and Validation of a Lighting Facility for the Objective Assessment of the Visual Performance of Presbyopic Patients in a Series of Activities of Daily Living

Abstract: Introduction The primary objective of this study is to develop and validate an experimental lighting facility that allows the evaluation of near and intermediate vision in different user-defined illuminance levels. Methods This is a prospective, randomized, controlled study. Normophakic patients populated three validation groups (VGs) according to their binocular uncorrected near visual acuity (UNVA): a) VG1, 0.0-0.1 logMAR; b) VG2, 0.4 logMAR; and c) VG3, 0.7 logMAR. All parti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(7 citation statements)
references
References 28 publications
0
7
0
Order By: Relevance
“…The present study was conducted in a special experimental facility constructed at the University Hospital of Alexandroupolis, as described in the corresponding validation study [ 22 ]. An advanced light diffusion system consisting of four linear LED luminaires was installed in a hospital room with a dimension of 6.87 m × 2.9 m × 3 m (depth × width × height) and flat white surface walls (reflectance: 70%).…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…The present study was conducted in a special experimental facility constructed at the University Hospital of Alexandroupolis, as described in the corresponding validation study [ 22 ]. An advanced light diffusion system consisting of four linear LED luminaires was installed in a hospital room with a dimension of 6.87 m × 2.9 m × 3 m (depth × width × height) and flat white surface walls (reflectance: 70%).…”
Section: Methodsmentioning
confidence: 99%
“…The four LED luminaires were mounted on the ceiling. The amount of the provided luminous flux and the exact luminaire positioning were defined using the RELUX light simulation tool (version 2021.1.1.0) (Relux Informatik AG, Münchenstein, Switzerland) before installation ( Figure 1 ) [ 22 ]. The confirmation of illuminance and on-site adjustments was carried out with the Extech Lux Meter EA30 (Extech Instruments Corporation, Nashua, NH, USA).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations