2018
DOI: 10.1016/j.foodchem.2018.01.092
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of an HPLC-MS/MS method with QuEChERS extraction using isotopic dilution to simultaneously analyze chlordecone and chlordecol in animal livers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
8
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 32 publications
(9 citation statements)
references
References 22 publications
1
8
0
Order By: Relevance
“…Today, GC is still used but coupled with mass spectrometry for its higher specificity, especially at low concentrations [10]. However, more recent studies use liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) preceded, or not, by an isotopic dilution for quantifying CLD in food, tissues, or biological fluids leading to an LOQ of only a few µg kg −1 [11][12][13].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Today, GC is still used but coupled with mass spectrometry for its higher specificity, especially at low concentrations [10]. However, more recent studies use liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) preceded, or not, by an isotopic dilution for quantifying CLD in food, tissues, or biological fluids leading to an LOQ of only a few µg kg −1 [11][12][13].…”
Section: Introductionmentioning
confidence: 99%
“…Then, an additional cleanup of the organic layer is performed with NaOH treatment and acidic lysis with sulfuric acid [10] or with a solid-phase extraction (SPE) step on Florisil ® cartridges [15]. More recently, a method dedicated to the analyses of CLD in animal liver [11,12], feces, and urine of ewes [11,12], based on QuEChERS method, was validated. Concerning the extraction procedure for blood samples (serum [13] or plasma [16]), it is based on a slightly simpler protocol originally dedicated to the extraction of polychlorobiphenyls (PCB) [15].…”
Section: Introductionmentioning
confidence: 99%
“…CMK-3 was selected as a sorbent to remove alkaloids, and PSA was selected to remove polar substances such as fatty acids in the sample matrix. 39,40 The amounts of CMK-3 and PSA were optimized to obtain the most efficient purication effect and pesticide recoveries. In the following optimization experiments, 6 mL of ACN was used to extract the analytes in the spiked FT samples at a concentration of 120 mg kg À1 , and 1 mL of the obtained extraction solutions was drawn for purication analysis.…”
Section: Optimization Of the Sorbent Amountmentioning
confidence: 99%
“…Although gas chromatography is still used, most of the current methods, including the official method for controls in France, are based on isotopic dilution followed by reversed-phase liquid chromatography analysis and tandem mass spectrometry detection with negative electrospray ionization (Clostre et al, 2015;Lastel et al, 2018;Saint-Hilaire et al, 2018). Isotopic dilution is recommended to ensure accurate identification and quantification.…”
Section: Introductionmentioning
confidence: 99%