2020
DOI: 10.1016/j.jksus.2020.05.005
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of anodic stripping voltammetry method for the determination of tretinoin in human urine and plasma using glassy carbon electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 22 publications
0
3
0
Order By: Relevance
“…[411] Direct determination of tretinoin (retinoids for cancer treatment) was carried out on GCE, however, obtained LOD value of 7.5 nM is questionable as lower concentration value of the reported LR equals to 1.0 mM. [412] Next, an amperometric sensor based on AuE modified with hierarchical leaf-like AuNPs electrochemically deposited using choline chloride as a shape directing agent was fabricated and used for vorinostat (histone deacetylase inhibitors) determination. [413] Moreover, sensing protocols based on cytochrome C modified BDDE (via monitoring a decrease in cytochrome C reduction peak) and SPCE modified with zinc-doped cobalt Fe 2 O 3 NPs (direct oxidation) have been reported for arsenic trioxide and anagrelide (other non-classified ANA), respectively.…”
Section: Other Antineoplastic Agentsmentioning
confidence: 99%
“…[411] Direct determination of tretinoin (retinoids for cancer treatment) was carried out on GCE, however, obtained LOD value of 7.5 nM is questionable as lower concentration value of the reported LR equals to 1.0 mM. [412] Next, an amperometric sensor based on AuE modified with hierarchical leaf-like AuNPs electrochemically deposited using choline chloride as a shape directing agent was fabricated and used for vorinostat (histone deacetylase inhibitors) determination. [413] Moreover, sensing protocols based on cytochrome C modified BDDE (via monitoring a decrease in cytochrome C reduction peak) and SPCE modified with zinc-doped cobalt Fe 2 O 3 NPs (direct oxidation) have been reported for arsenic trioxide and anagrelide (other non-classified ANA), respectively.…”
Section: Other Antineoplastic Agentsmentioning
confidence: 99%
“… 20 Additionally, breakthrough progress was achieved for human urine and plasma samples in 2020 by the ASV (anodic stripping voltammetry) method. 21 As far as we know, only the last three research papers were reported in the last decade within the electrochemistry method domain for RA detection (Table S1 † ). In this field, it is still a challenge to produce novel electrode materials and suitable electrochemical methods to improve sensitivity, accuracy, simple operation without pretreatment, low cost, and a fast response time in real-time analysis.…”
Section: Introductionmentioning
confidence: 99%
“…There are many UV spectroscopic methods [ 10 13 ] in addition to high-performance liquid chromatography (HPLC) [ 14 19 ] and electrochemical methods [ 20 22 ], to determine NCT or TRT in combination with other active ingredients. However, no previous studies have developed a method to estimate NCT and TRT simultaneously in a binary mixture or in a pharmaceutical preparation.…”
Section: Introductionmentioning
confidence: 99%