2016
DOI: 10.3329/bpj.v19i1.29247
|View full text |Cite
|
Sign up to set email alerts
|

Development and Validation of HPTLC Method for Simultaneous Estimation of Emtricitabine, Rilpivirine and Tenofovir Disoproxil Fumarate in Combined Dosage form

Abstract: This study describes the development and validation of high performance thin layer chromatographic (HPTLC) method for the simultaneous estimation of Emtricitabine (EMT), Rilpivirine (RPV) and Tenofovir disoproxil fumarate (TFV) in combined dosage form. Chromatographic separation of these drugs was performed on aluminum plates precoated with silica gel 60 F254 as the stationary phase using solvent system consisted of chloroform: ethyl acetate: methanol: glacial acetic acid (5:2:1:0.1 v/v/v/v). The densitometric… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 3 publications
0
7
0
Order By: Relevance
“… 33 On the other hand, the precision and accuracy of all the reported HPTLC methods were found to be much better than the routine NP-HPTLC method. 29 34 The accuracy of literature HPTLC methods was found to be similar to the green RP-HPTLC method. Although, the precision of the literature HPTLC methods was found to be superior to the green RP-HPTLC method, but the precision values for the literature and green RP-HPTLC method were within the limit of ICH guidance (less than 2%).…”
Section: Resultsmentioning
confidence: 69%
See 4 more Smart Citations
“… 33 On the other hand, the precision and accuracy of all the reported HPTLC methods were found to be much better than the routine NP-HPTLC method. 29 34 The accuracy of literature HPTLC methods was found to be similar to the green RP-HPTLC method. Although, the precision of the literature HPTLC methods was found to be superior to the green RP-HPTLC method, but the precision values for the literature and green RP-HPTLC method were within the limit of ICH guidance (less than 2%).…”
Section: Resultsmentioning
confidence: 69%
“…However, the lower limit of quantification (LLOQ) of these methods was much lower than the green and routine densitometry method in this study. [29][30][31]34 The linearity for the other two literature HPTLC methods has been reported as 30−1100 ng/band 32 and 40− 400 ng/band, 33 respectively. The accuracy and precision of these two methods were also within the limit of ICH guidance.…”
Section: Resultsmentioning
confidence: 97%
See 3 more Smart Citations