2015
DOI: 10.1016/j.ejmp.2015.05.009
|View full text |Cite
|
Sign up to set email alerts
|

Development of a 3D optical scanner for evaluating patient-specific dose distributions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 16 publications
0
4
0
Order By: Relevance
“…Pretreatment patient-specific delivery quality assurance (DQA) is essential for the verification of accurate dose delivery in advanced radiation therapy techniques, such as intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy, stereotactic body radiation therapy, and helical tomotherapy (HT). 1 -4…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Pretreatment patient-specific delivery quality assurance (DQA) is essential for the verification of accurate dose delivery in advanced radiation therapy techniques, such as intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy, stereotactic body radiation therapy, and helical tomotherapy (HT). 1 -4…”
Section: Introductionmentioning
confidence: 99%
“…Pretreatment patient-specific delivery quality assurance (DQA) is essential for the verification of accurate dose delivery in advanced radiation therapy techniques, such as intensitymodulated radiation therapy (IMRT), volumetric modulated arc therapy, stereotactic body radiation therapy, and helical tomotherapy (HT). [1][2][3][4] An HT system is an IMRT delivery system that delivers the radiation beam with a high degree of conformity; it is an imageguided system using megavoltage computed tomography (CT). 5 The radiation beam is delivered using a 6-MV linear accelerator continually while the couch is moving into the gantry, and intensity modulation is achieved with a binary multileaf collimator (MLC).…”
Section: Introductionmentioning
confidence: 99%
“…Aqueous solution of Alizarin yellow GG (AY-GG) undergoes degradation under the effect of radiation (Sun et al , 2013). In the present study, murexide, a reddish-purple compound, has received much interest because of its application in chemical analysis and spectrophotometric fields (Abtahi and Poughanbari, 2018; Chang et al , 2015).…”
Section: Introductionmentioning
confidence: 99%
“…Scan speed was 10 slices min −1 , giving a 5 min acquisition time for a typical 50 slice scan of voxel size 0.3 × 0.3 × 1.0 mm, or 17 min for 0.3 mm isotropic voxels. This level of acquisition time is comparable to broad beam scanners (Olding et al 2010, Thomas et al 2011, although a sub-minute cone beam scanner has been recently reported (Chang et al 2016).…”
Section: Optical Ct Scanner Designmentioning
confidence: 67%