2022
DOI: 10.1016/j.bioelechem.2022.108057
|View full text |Cite
|
Sign up to set email alerts
|

Development of a biosensor for phosphorylated Tau 181 protein detection in Early-Stage Alzheimer’s disease

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(6 citation statements)
references
References 26 publications
0
6
0
Order By: Relevance
“… Technique Sensing platform Sample Linear range LOD Refs. EIS Ab/Protein G/3,3'-dithiobis(sulfosuccinimidyl propionate) (DTSSP)/Gold Electrode BSA & Human serum 0.01 pM to 10 nM 0.03 pM 63 DPV Aptamer-Au-CS bioconjugate /BSA/Ab/MPA/Gold Electrode Human serum 0.5 pM to 100 pM 0.42 pM 64 EIS 3-aminophenol MIP/C-SPE PBS 2.18 pM to 2.18 nM 0.024 pM 65 EIS n-butylamine/Ab/lipoic acid/Au Electrode PBS 100 μg/mL 66 DPV carbon nanocomposite film composed of MWCNTs, rGO, and CS/Gold Electrode Human serum 0.5–80 fM 0.46 fM 67 DPV Apt/AuNPs/Paper-based vertical graphene electrode (VGE) Blood 0.1 pg/mL to 1 ng/mL 0.034 pg/mL 68 SWV, CV Ab/MWCNTs-PAH/Pt/C-SPE Serum 8.6–1100 pg/mL 0.24 pg/mL 69 Amperometric HRP-DAb/tau/capture antibody/AuNPs-PAMAM/C-SPE Undiluted human plasma and brain tissue extracts 11–800 pg mL …”
Section: Resultsmentioning
confidence: 99%
“… Technique Sensing platform Sample Linear range LOD Refs. EIS Ab/Protein G/3,3'-dithiobis(sulfosuccinimidyl propionate) (DTSSP)/Gold Electrode BSA & Human serum 0.01 pM to 10 nM 0.03 pM 63 DPV Aptamer-Au-CS bioconjugate /BSA/Ab/MPA/Gold Electrode Human serum 0.5 pM to 100 pM 0.42 pM 64 EIS 3-aminophenol MIP/C-SPE PBS 2.18 pM to 2.18 nM 0.024 pM 65 EIS n-butylamine/Ab/lipoic acid/Au Electrode PBS 100 μg/mL 66 DPV carbon nanocomposite film composed of MWCNTs, rGO, and CS/Gold Electrode Human serum 0.5–80 fM 0.46 fM 67 DPV Apt/AuNPs/Paper-based vertical graphene electrode (VGE) Blood 0.1 pg/mL to 1 ng/mL 0.034 pg/mL 68 SWV, CV Ab/MWCNTs-PAH/Pt/C-SPE Serum 8.6–1100 pg/mL 0.24 pg/mL 69 Amperometric HRP-DAb/tau/capture antibody/AuNPs-PAMAM/C-SPE Undiluted human plasma and brain tissue extracts 11–800 pg mL …”
Section: Resultsmentioning
confidence: 99%
“…In cases where the capacitive behavior is not ideal, it is represented by a frequencydependent element called a constant phase element (CPE), instead of C dl for the double layer, which is defined by a value and the coefficient of CPE. The impedance CPE is defined as in (2).…”
Section: Resultsmentioning
confidence: 99%
“…Point-of-care biosensors present a promising solution for the regular monitoring of biomarkers for the early diagnosis of diseases like cancer [ 1 ], Alzheimer’s disease [ 2 ] and metabolic disorders [ 3 ]. Biosensors employ either a labeled approach or a label-free approach as the underlying principle.…”
Section: Introductionmentioning
confidence: 99%
“…There are several potential POC devices reporting the analysis of inflammation biomarkers, such as cortisol [ 157 159 ], C-reactive protein [ 160 162 ], Tau protein [ 163 166 ], or S-100B [ 167 ]. For example, cortisol was analyzed using an impedimetric SPCE-modified electrochemical cell [ 157 ] and a voltammetric Au-interdigitated modified microelectrode [ 158 ] from saliva and plasma, respectively.…”
Section: Biomarkers Involved In Inflammatory Diseasesmentioning
confidence: 99%